Understanding Labor Inclusions in Contracts

Understanding Labor Inclusions in Contracts

Overview of mobile home HVAC systems and their components

Mobile homes, often celebrated for their affordability and flexibility, require specialized care when it comes to heating, ventilation, and air conditioning (HVAC) systems. These systems are integral to maintaining a comfortable living environment regardless of the season. Understanding how these HVAC systems work and what labor inclusions exist in related contracts is crucial for homeowners looking to optimize comfort while ensuring financial prudence.


To begin with, mobile home HVAC systems are typically smaller and more compact than those found in traditional residential homes. This is due to the size constraints inherent in mobile home construction. The most common types include packaged units that combine heating and cooling functions into one unit, as well as split systems where components are divided between indoor and outdoor units. These systems must be carefully selected to suit the specific needs of a mobile home's limited space while providing efficient climate control.


High SEER-rated units are recommended for mobile home energy savings mobile home hvac replacement cost crawl space.

When considering installation or maintenance contracts for these HVAC systems, understanding labor inclusions is essential. Labor costs can make up a significant portion of any service contract or installation agreement. Therefore, knowing what tasks are covered can help homeowners avoid unexpected expenses and ensure that they receive comprehensive care for their system.


Typically, labor inclusions in HVAC contracts will cover the installation of new units, which involves setting up the equipment according to manufacturer specifications and connecting necessary electrical or fuel lines. It also usually includes system testing to confirm proper operation post-installation. For maintenance agreements, labor coverage might include routine inspections such as checking refrigerant levels, cleaning coils or filters, calibrating thermostats, and examining ductwork for leaks.


However, not all labor-related tasks may be included in standard contracts. Homeowners should be aware that additional services like extensive duct cleaning or emergency repairs outside regular business hours could incur extra charges unless explicitly stated otherwise in the contract terms.


In conclusion, having a clear understanding of mobile home HVAC systems alongside knowledge about labor inclusions within service contracts empowers homeowners to make informed decisions regarding their climate control needs. This comprehension not only aids in selecting suitable equipment but also ensures that financial resources are allocated efficiently without unforeseen costs overshadowing the overall benefits provided by a well-maintained HVAC system. As with any contractual agreement, clarity on coverage specifics remains key to achieving long-term satisfaction with one's investment in home comfort solutions.

In the realm of construction and mechanical services, particularly within the Heating, Ventilation, and Air Conditioning (HVAC) sector, the clarity of contractual agreements can significantly impact project outcomes. One critical aspect of these agreements is specifying labor inclusions. Understanding and detailing labor inclusions in HVAC installation contracts is not merely a matter of procedural formality; it plays a pivotal role in safeguarding both parties' interests and ensuring the seamless execution of projects.


To begin with, specifying labor inclusions provides transparency. An HVAC installation involves various tasks ranging from system design and site preparation to equipment installation and testing. By clearly outlining which tasks are included under the labor scope in a contract, all parties involved-contractors, subcontractors, and clients-can have a unified understanding of what is expected. This transparency reduces ambiguities that often lead to disputes or misunderstandings during project execution.


Furthermore, detailed labor inclusions help in accurate cost estimation. Costs associated with HVAC installations can be substantial; hence, having a precise breakdown of labor activities allows for better budgeting. Contractors can allocate resources effectively while clients gain insight into where their investment is being directed. This clarity aids in preventing unexpected expenses that might arise from assuming certain tasks were included when they were not.


Another dimension to consider is risk management. By explicitly stating what labor is covered within an HVAC contract, contractors can mitigate risks associated with scope creep-where additional tasks are added without clear agreement or compensation. It ensures that any work beyond the specified scope must be renegotiated and adequately compensated for, protecting contractors from unanticipated workload increases without corresponding financial adjustment.


From an operational perspective, specifying labor inclusions fosters efficient project management. With defined responsibilities laid out from the onset, teams can plan their workflow more effectively. It enhances coordination among different stakeholders as everyone knows their role within the larger framework of the installation process. Such organization minimizes delays caused by task overlaps or omissions.


Moreover, well-documented labor inclusions set standards for quality assurance. When expectations are defined clearly in terms of who does what and how it should be done, maintaining quality becomes easier to manage and evaluate against predetermined criteria.


Lastly, establishing thorough labor specifications cultivates trust between contracting parties. When clients see that every detail has been considered and documented professionally, it builds confidence in the contractor's commitment to deliver on promises made-a cornerstone for fostering long-term business relationships.


In conclusion, specifying labor inclusions within HVAC installation contracts transcends being just a contractual obligation; it establishes a foundation for successful project delivery through enhanced clarity, cost control, risk mitigation, efficient management practices, quality assurance standards adherence-and ultimately building trust amongst engaged entities. As such complexity defines modern-day construction ventures increasingly so does necessity dictate precision-in this case via detailed articulation about who does what when where why-and importantly at what cost!

Overcoming space limitations for HVAC installation in mobile homes

Overcoming space limitations for HVAC installation in mobile homes

In the quest for comfort and sustainability, mobile homes present unique challenges, particularly when it comes to installing HVAC systems.. These compact living spaces require innovative solutions that not only fit within their limited confines but also operate efficiently.

Posted by on 2024-12-28

Addressing weight constraints for rooftop HVAC units

Addressing weight constraints for rooftop HVAC units

In the evolving landscape of modern architecture and building design, one challenge that frequently emerges is addressing weight constraints for rooftop HVAC units.. As buildings strive to achieve a delicate balance between functionality and sustainability, lightweight HVAC systems have emerged as a game-changer in the industry.

Posted by on 2024-12-28

Planning HVAC installations in tight mobile home crawl spaces

Planning HVAC installations in tight mobile home crawl spaces

Installing HVAC systems in the tight confines of mobile home crawl spaces can be a challenging endeavor.. These areas often present unique obstacles that require careful planning and innovative solutions to ensure successful installation.

Posted by on 2024-12-28

Ensuring proper ventilation for mobile home HVAC systems

Ensuring proper ventilation for mobile home HVAC systems

Ensuring proper ventilation for mobile home HVAC systems is an essential aspect of maintaining a healthy and comfortable living environment.. This process, however, is not just about improving air quality; it also involves adhering to safety considerations and complying with local building codes.

Posted by on 2024-12-28

Considerations for maintaining structural integrity during HVAC installation

When it comes to the world of mobile home HVAC (heating, ventilation, and air conditioning) systems, understanding the intricacies of labor components in contracts is crucial for homeowners. These contracts form the backbone of any installation or maintenance project, ensuring that all parties are well aware of their responsibilities and expectations. Yet, deciphering what exactly is included under "labor components" can often be a daunting task for those unfamiliar with industry jargon.


At its core, the term "common labor components" in mobile home HVAC contracts refers to the essential tasks and services that technicians perform as part of installing or maintaining an HVAC system. These components typically encompass a wide range of activities designed to ensure that the system operates efficiently and safely within a mobile home setting.


One primary labor component involves the initial assessment and planning phase. This step includes evaluating the mobile home's specific requirements, such as size, layout, and insulation levels, to determine the most suitable HVAC system. Technicians must also consider any existing infrastructure and potential obstacles that might affect installation. This thorough evaluation ensures that both contractor and homeowner are aligned on what needs to be done.


Following this assessment is the installation process itself. Common labor tasks during this phase include setting up ductwork, mounting units-whether they be air conditioners or heaters-and connecting necessary electrical wiring. In mobile homes especially, where space can be limited and configurations unique, precision in these tasks is paramount. Technicians need to carefully navigate these constraints while ensuring compliance with local building codes.


Maintenance services also fall under common labor components in HVAC contracts. Regular check-ups are vital for extending the life of an HVAC system and maintaining its efficiency over time. Tasks may involve cleaning filters, inspecting ducts for leaks or blockages, checking refrigerant levels in air conditioning units, and testing thermostats for accuracy. By including these routine checks in a contract's labor components section, homeowners can rest assured knowing their investment is protected against premature wear and tear.


It's equally important for homeowners to understand what might not be covered under standard labor inclusions. For instance, any major structural changes needed to accommodate new systems or extensive repairs due to pre-existing damage might incur additional costs beyond standard labor fees outlined in a contract.


Ultimately, clear communication about common labor components helps avoid misunderstandings between homeowners and contractors. It's advisable for homeowners to thoroughly review contract terms before agreeing to them-and don't hesitate to ask questions if any aspect regarding labor seems unclear.


In summary, comprehending common labor components in mobile home HVAC contracts is vital for anyone looking into installing or maintaining such systems within their property. By understanding what tasks are typically included-and which ones might require extra negotiation-homeowners can enter agreements confidently knowing they're adequately informed about their investment's scope of work.

Considerations for maintaining structural integrity during HVAC installation

Strategies for evenly distributing weight across the roof when adding or upgrading HVAC systems

In the complex world of contract law, clear and precise language is paramount. This is particularly true when it comes to labor terms within contracts, as ambiguity in these terms can lead to a host of potential issues that can affect both employers and employees alike. Understanding labor inclusions in contracts requires careful consideration of the terminology used to define roles, responsibilities, and expectations.


One major issue with ambiguous labor terms is the risk of misinterpretation. When a contract includes vague or unclear language regarding job duties or employment conditions, both parties may have differing interpretations of what those terms actually mean. For instance, if a contract simply states that an employee will perform "various tasks as needed," without specifying what those tasks might entail, it leaves room for disagreement over what constitutes reasonable work expectations.


This lack of clarity can also lead to disputes over compensation and benefits. Ambiguous language concerning payment structures, overtime eligibility, or bonus criteria can result in disagreements that may require legal intervention to resolve. Employees might believe they are entitled to certain compensations based on their understanding of the contract's terms, while employers might have an entirely different interpretation.


Moreover, ambiguous labor terms pose significant challenges during performance evaluations and disciplinary actions. Without clearly defined job descriptions and performance metrics, assessing an employee's work becomes subjective and potentially unfair. This could lead to dissatisfaction among employees who feel they are being evaluated against shifting standards or arbitrary criteria.


The potential for litigation is another critical issue arising from ambiguous labor terms. Disagreements stemming from unclear contract provisions often escalate into legal disputes that consume time and resources for all parties involved. Employers may face lawsuits alleging breach of contract or unfair labor practices if employees believe their rights under the contract have been violated due to ambiguities.


To mitigate these potential issues, it is crucial for contracts to be drafted with precision and care. Employers should strive to use clear language when defining roles and responsibilities, specifying work hours, outlining compensation structures, and detailing any other employment conditions. Additionally, involving legal experts in the drafting process can help ensure that contracts meet legal standards while minimizing ambiguities.


In conclusion, ambiguity in labor terms within contracts poses significant risks that can lead to misunderstandings, disputes over compensation and benefits, challenges in evaluating performance fairly, and even litigation. By prioritizing clarity in contractual language and seeking professional guidance during the drafting process, employers can foster more harmonious working relationships with their employees while safeguarding against potential conflicts down the line. Ultimately, understanding labor inclusions in contracts is not just about legal compliance; it's about building trust through transparency and mutual understanding between both parties involved.

Potential risks of improper weight distribution on mobile home roofs and HVAC efficiency

When it comes to crafting HVAC contracts, one of the most critical components is the clear delineation of labor inclusions. Understanding and articulating labor inclusions effectively can prevent disputes, foster transparency, and ensure a smooth working relationship between contractors and clients. Best practices in this area are essential for both parties to be fully aware of their responsibilities and expectations, ultimately leading to successful project completion.


First and foremost, clarity is key. An HVAC contract should clearly specify what labor services are included in the agreement. This typically involves listing out tasks such as installation, maintenance, repair work, or any other service that falls under the contractor's purview. By being explicit about these details, contractors eliminate ambiguity, which can often lead to misunderstandings or disputes down the line.


Additionally, it is important for contracts to outline not only what is included but also what is excluded from the labor provisions. Specifying exclusions helps manage client expectations by clarifying what additional charges might arise if further services are needed beyond those initially agreed upon. For instance, emergency repairs or after-hours services could be listed as exclusions unless otherwise negotiated.


Another best practice involves defining the scope of work with precision. This includes detailing timelines for each phase of the project and specifying the number of workers assigned to different tasks if applicable. Having a well-defined scope ensures that both parties have a mutual understanding of how long tasks should take and who will be responsible for them.


Moreover, including a breakdown of costs associated with labor inclusions can further enhance transparency. Providing an itemized list that separates labor costs from material costs allows clients to see exactly where their money is going. This practice not only builds trust but also aids in budget management on both sides.


Communication plays a pivotal role in reinforcing these best practices. Before finalizing any contract, it's advisable for contractors to discuss all terms related to labor inclusions with their clients thoroughly. Such discussions provide an opportunity for questions to be answered and adjustments to be made before legal commitments are established.


Lastly, regular updates during the course of the project should not be overlooked. As projects progress, unforeseen circumstances may necessitate changes in scope or timelines; keeping open lines of communication ensures that any modifications are mutually agreed upon and documented appropriately within contract amendments if needed.


In conclusion, implementing best practices for clear labor inclusions in HVAC contracts involves more than just drafting precise language; it requires ongoing communication and collaboration between parties involved. By focusing on clarity, specificity regarding inclusions and exclusions, transparent cost breakdowns, thorough pre-contract discussions, and consistent updates throughout project execution-contractors can pave the way for successful engagements characterized by minimal disputes and maximum satisfaction on all fronts.

Guidelines for professional assessment and installation to ensure balanced weight distribution

In the intricate landscape of business transactions, contractual agreements serve as the backbone that holds parties accountable and ensures mutual understanding. One pivotal aspect of such agreements is the inclusion of labor considerations, which not only defines the working relationship but also safeguards both parties' interests. Navigating legal considerations and compliance in this realm requires meticulous attention to detail and a deep understanding of applicable laws and regulations.


At its core, a labor inclusion clause in a contract delineates the expectations and obligations related to employment or services provided. These clauses can encompass a variety of elements, including but not limited to wages, working hours, benefits, dispute resolution mechanisms, termination conditions, and nondisclosure agreements. The precise language used in these clauses is crucial because it establishes the framework for how labor-related issues will be managed throughout the contract's duration.


Legal considerations are paramount when drafting labor inclusions. Laws governing employment contracts can vary significantly from one jurisdiction to another, influenced by national legislation as well as regional or state-specific mandates. Key regulations often include minimum wage laws, overtime requirements, health and safety standards, anti-discrimination statutes, and workers' compensation provisions. Failure to comply with these legal requisites can lead to severe penalties, including fines or legal action against offending parties.


Moreover, compliance with established labor laws not only avoids legal repercussions but also fosters a more ethical work environment. By adhering to these standards, organizations demonstrate their commitment to fair treatment and respect for workers' rights. This commitment can enhance an organization's reputation and contribute positively to employee morale and productivity.


Another critical consideration is ensuring that contracts are equitable for all parties involved. Unbalanced agreements that disproportionately favor one party over another may lead to disputes or even contract voidance if deemed unconscionable by a court of law. Therefore, transparency during negotiations is vital; both parties should clearly understand their rights and responsibilities before signing any agreement.


Furthermore, globalization has introduced additional layers of complexity into labor inclusions within contracts. When dealing with international partners or employees across borders, it's essential to consider cross-jurisdictional differences in labor laws. This might necessitate consultation with legal experts who specialize in international employment law to ensure full compliance with all relevant rules.


In conclusion, understanding labor inclusions in contractual agreements involves more than simply drafting terms on paper; it encompasses rigorous adherence to legal standards alongside ethical practices that honor worker rights. Businesses must remain vigilant about evolving legislation while aiming for transparency and fairness in all their dealings. In doing so, they not only protect themselves from potential litigation but also promote a culture of trust-an invaluable asset in today's interconnected world economy.

 

An ab anbar (water reservoir) with double domes and windcatchers (openings near the top of the towers) in the central desert city of Naeen, Iran. Windcatchers are a form of natural ventilation.[1]

Ventilation is the intentional introduction of outdoor air into a space. Ventilation is mainly used to control indoor air quality by diluting and displacing indoor pollutants; it can also be used to control indoor temperature, humidity, and air motion to benefit thermal comfort, satisfaction with other aspects of the indoor environment, or other objectives.

The intentional introduction of outdoor air is usually categorized as either mechanical ventilation, natural ventilation, or mixed-mode ventilation.[2]

  • Mechanical ventilation is the intentional fan-driven flow of outdoor air into and/or out from a building. Mechanical ventilation systems may include supply fans (which push outdoor air into a building), exhaust[3] fans (which draw air out of a building and thereby cause equal ventilation flow into a building), or a combination of both (called balanced ventilation if it neither pressurizes nor depressurizes the inside air,[3] or only slightly depressurizes it). Mechanical ventilation is often provided by equipment that is also used to heat and cool a space.
  • Natural ventilation is the intentional passive flow of outdoor air into a building through planned openings (such as louvers, doors, and windows). Natural ventilation does not require mechanical systems to move outdoor air. Instead, it relies entirely on passive physical phenomena, such as wind pressure, or the stack effect. Natural ventilation openings may be fixed, or adjustable. Adjustable openings may be controlled automatically (automated), owned by occupants (operable), or a combination of both. Cross ventilation is a phenomenon of natural ventilation.
  • Mixed-mode ventilation systems use both mechanical and natural processes. The mechanical and natural components may be used at the same time, at different times of day, or in different seasons of the year.[4] Since natural ventilation flow depends on environmental conditions, it may not always provide an appropriate amount of ventilation. In this case, mechanical systems may be used to supplement or regulate the naturally driven flow.

Ventilation is typically described as separate from infiltration.

  • Infiltration is the circumstantial flow of air from outdoors to indoors through leaks (unplanned openings) in a building envelope. When a building design relies on infiltration to maintain indoor air quality, this flow has been referred to as adventitious ventilation.[5]

The design of buildings that promote occupant health and well-being requires a clear understanding of the ways that ventilation airflow interacts with, dilutes, displaces, or introduces pollutants within the occupied space. Although ventilation is an integral component of maintaining good indoor air quality, it may not be satisfactory alone.[6] A clear understanding of both indoor and outdoor air quality parameters is needed to improve the performance of ventilation in terms of occupant health and energy.[7] In scenarios where outdoor pollution would deteriorate indoor air quality, other treatment devices such as filtration may also be necessary.[8] In kitchen ventilation systems, or for laboratory fume hoods, the design of effective effluent capture can be more important than the bulk amount of ventilation in a space. More generally, the way that an air distribution system causes ventilation to flow into and out of a space impacts the ability of a particular ventilation rate to remove internally generated pollutants. The ability of a system to reduce pollution in space is described as its "ventilation effectiveness". However, the overall impacts of ventilation on indoor air quality can depend on more complex factors such as the sources of pollution, and the ways that activities and airflow interact to affect occupant exposure.

An array of factors related to the design and operation of ventilation systems are regulated by various codes and standards. Standards dealing with the design and operation of ventilation systems to achieve acceptable indoor air quality include the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) Standards 62.1 and 62.2, the International Residential Code, the International Mechanical Code, and the United Kingdom Building Regulations Part F. Other standards that focus on energy conservation also impact the design and operation of ventilation systems, including ASHRAE Standard 90.1, and the International Energy Conservation Code.

When indoor and outdoor conditions are favorable, increasing ventilation beyond the minimum required for indoor air quality can significantly improve both indoor air quality and thermal comfort through ventilative cooling, which also helps reduce the energy demand of buildings.[9][10] During these times, higher ventilation rates, achieved through passive or mechanical means (air-side economizer, ventilative pre-cooling), can be particularly beneficial for enhancing people's physical health.[11] Conversely, when conditions are less favorable, maintaining or improving indoor air quality through ventilation may require increased use of mechanical heating or cooling, leading to higher energy consumption.

Ventilation should be considered for its relationship to "venting" for appliances and combustion equipment such as water heaters, furnaces, boilers, and wood stoves. Most importantly, building ventilation design must be careful to avoid the backdraft of combustion products from "naturally vented" appliances into the occupied space. This issue is of greater importance for buildings with more air-tight envelopes. To avoid the hazard, many modern combustion appliances utilize "direct venting" which draws combustion air directly from outdoors, instead of from the indoor environment.

Design of air flow in rooms

[edit]

The air in a room can be supplied and removed in several ways, for example via ceiling ventilation, cross ventilation, floor ventilation or displacement ventilation.[citation needed]

Furthermore, the air can be circulated in the room using vortexes which can be initiated in various ways:

Ventilation rates for indoor air quality

[edit]

The ventilation rate, for commercial, industrial, and institutional (CII) buildings, is normally expressed by the volumetric flow rate of outdoor air, introduced to the building. The typical units used are cubic feet per minute (CFM) in the imperial system, or liters per second (L/s) in the metric system (even though cubic meter per second is the preferred unit for volumetric flow rate in the SI system of units). The ventilation rate can also be expressed on a per person or per unit floor area basis, such as CFM/p or CFM/ft², or as air changes per hour (ACH).

Standards for residential buildings

[edit]

For residential buildings, which mostly rely on infiltration for meeting their ventilation needs, a common ventilation rate measure is the air change rate (or air changes per hour): the hourly ventilation rate divided by the volume of the space (I or ACH; units of 1/h). During the winter, ACH may range from 0.50 to 0.41 in a tightly air-sealed house to 1.11 to 1.47 in a loosely air-sealed house.[12]

ASHRAE now recommends ventilation rates dependent upon floor area, as a revision to the 62-2001 standard, in which the minimum ACH was 0.35, but no less than 15 CFM/person (7.1 L/s/person). As of 2003, the standard has been changed to 3 CFM/100 sq. ft. (15 L/s/100 sq. m.) plus 7.5 CFM/person (3.5 L/s/person).[13]

Standards for commercial buildings

[edit]

Ventilation rate procedure

[edit]

Ventilation Rate Procedure is rate based on standard and prescribes the rate at which ventilation air must be delivered to space and various means to the condition that air.[14] Air quality is assessed (through CO2 measurement) and ventilation rates are mathematically derived using constants. Indoor Air Quality Procedure uses one or more guidelines for the specification of acceptable concentrations of certain contaminants in indoor air but does not prescribe ventilation rates or air treatment methods.[14] This addresses both quantitative and subjective evaluations and is based on the Ventilation Rate Procedure. It also accounts for potential contaminants that may have no measured limits, or for which no limits are not set (such as formaldehyde off-gassing from carpet and furniture).

Natural ventilation

[edit]

Natural ventilation harnesses naturally available forces to supply and remove air in an enclosed space. Poor ventilation in rooms is identified to significantly increase the localized moldy smell in specific places of the room including room corners.[11] There are three types of natural ventilation occurring in buildings: wind-driven ventilation, pressure-driven flows, and stack ventilation.[15] The pressures generated by 'the stack effect' rely upon the buoyancy of heated or rising air. Wind-driven ventilation relies upon the force of the prevailing wind to pull and push air through the enclosed space as well as through breaches in the building's envelope.

Almost all historic buildings were ventilated naturally.[16] The technique was generally abandoned in larger US buildings during the late 20th century as the use of air conditioning became more widespread. However, with the advent of advanced Building Performance Simulation (BPS) software, improved Building Automation Systems (BAS), Leadership in Energy and Environmental Design (LEED) design requirements, and improved window manufacturing techniques; natural ventilation has made a resurgence in commercial buildings both globally and throughout the US.[17]

The benefits of natural ventilation include:

  • Improved indoor air quality (IAQ)
  • Energy savings
  • Reduction of greenhouse gas emissions
  • Occupant control
  • Reduction in occupant illness associated with sick building syndrome
  • Increased worker productivity

Techniques and architectural features used to ventilate buildings and structures naturally include, but are not limited to:

  • Operable windows
  • Clerestory windows and vented skylights
  • Lev/convection doors
  • Night purge ventilation
  • Building orientation
  • Wind capture façades

Airborne diseases

[edit]

Natural ventilation is a key factor in reducing the spread of airborne illnesses such as tuberculosis, the common cold, influenza, meningitis or COVID-19.[18] Opening doors and windows are good ways to maximize natural ventilation, which would make the risk of airborne contagion much lower than with costly and maintenance-requiring mechanical systems. Old-fashioned clinical areas with high ceilings and large windows provide the greatest protection. Natural ventilation costs little and is maintenance-free, and is particularly suited to limited-resource settings and tropical climates, where the burden of TB and institutional TB transmission is highest. In settings where respiratory isolation is difficult and climate permits, windows and doors should be opened to reduce the risk of airborne contagion. Natural ventilation requires little maintenance and is inexpensive.[19]

Natural ventilation is not practical in much of the infrastructure because of climate. This means that the facilities need to have effective mechanical ventilation systems and or use Ceiling Level UV or FAR UV ventilation systems.

Ventilation is measured in terms of air changes per hour (ACH). As of 2023, the CDC recommends that all spaces have a minimum of 5 ACH.[20] For hospital rooms with airborne contagions the CDC recommends a minimum of 12 ACH.[21] Challenges in facility ventilation are public unawareness,[22][23] ineffective government oversight, poor building codes that are based on comfort levels, poor system operations, poor maintenance, and lack of transparency.[24]

Pressure, both political and economic, to improve energy conservation has led to decreased ventilation rates. Heating, ventilation, and air conditioning rates have dropped since the energy crisis in the 1970s and the banning of cigarette smoke in the 1980s and 1990s.[25][26][better source needed]

Mechanical ventilation

[edit]
An axial belt-drive exhaust fan serving an underground car park. This exhaust fan's operation is interlocked with the concentration of contaminants emitted by internal combustion engines.

Mechanical ventilation of buildings and structures can be achieved by the use of the following techniques:

  • Whole-house ventilation
  • Mixing ventilation
  • Displacement ventilation
  • Dedicated subaerial air supply

Demand-controlled ventilation (DCV)

[edit]

Demand-controlled ventilation (DCV, also known as Demand Control Ventilation) makes it possible to maintain air quality while conserving energy.[27][28] ASHRAE has determined that "It is consistent with the ventilation rate procedure that demand control be permitted for use to reduce the total outdoor air supply during periods of less occupancy."[29] In a DCV system, CO2 sensors control the amount of ventilation.[30][31] During peak occupancy, CO2 levels rise, and the system adjusts to deliver the same amount of outdoor air as would be used by the ventilation-rate procedure.[32] However, when spaces are less occupied, CO2 levels reduce, and the system reduces ventilation to conserves energy. DCV is a well-established practice,[33] and is required in high occupancy spaces by building energy standards such as ASHRAE 90.1.[34]

Personalized ventilation

[edit]

Personalized ventilation is an air distribution strategy that allows individuals to control the amount of ventilation received. The approach delivers fresh air more directly to the breathing zone and aims to improve the air quality of inhaled air. Personalized ventilation provides much higher ventilation effectiveness than conventional mixing ventilation systems by displacing pollution from the breathing zone with far less air volume. Beyond improved air quality benefits, the strategy can also improve occupants' thermal comfort, perceived air quality, and overall satisfaction with the indoor environment. Individuals' preferences for temperature and air movement are not equal, and so traditional approaches to homogeneous environmental control have failed to achieve high occupant satisfaction. Techniques such as personalized ventilation facilitate control of a more diverse thermal environment that can improve thermal satisfaction for most occupants.

Local exhaust ventilation

[edit]

Local exhaust ventilation addresses the issue of avoiding the contamination of indoor air by specific high-emission sources by capturing airborne contaminants before they are spread into the environment. This can include water vapor control, lavatory effluent control, solvent vapors from industrial processes, and dust from wood- and metal-working machinery. Air can be exhausted through pressurized hoods or the use of fans and pressurizing a specific area.[35]
A local exhaust system is composed of five basic parts:

  1. A hood that captures the contaminant at its source
  2. Ducts for transporting the air
  3. An air-cleaning device that removes/minimizes the contaminant
  4. A fan that moves the air through the system
  5. An exhaust stack through which the contaminated air is discharged[35]

In the UK, the use of LEV systems has regulations set out by the Health and Safety Executive (HSE) which are referred to as the Control of Substances Hazardous to Health (CoSHH). Under CoSHH, legislation is set to protect users of LEV systems by ensuring that all equipment is tested at least every fourteen months to ensure the LEV systems are performing adequately. All parts of the system must be visually inspected and thoroughly tested and where any parts are found to be defective, the inspector must issue a red label to identify the defective part and the issue.

The owner of the LEV system must then have the defective parts repaired or replaced before the system can be used.

Smart ventilation

[edit]

Smart ventilation is a process of continually adjusting the ventilation system in time, and optionally by location, to provide the desired IAQ benefits while minimizing energy consumption, utility bills, and other non-IAQ costs (such as thermal discomfort or noise). A smart ventilation system adjusts ventilation rates in time or by location in a building to be responsive to one or more of the following: occupancy, outdoor thermal and air quality conditions, electricity grid needs, direct sensing of contaminants, operation of other air moving and air cleaning systems. In addition, smart ventilation systems can provide information to building owners, occupants, and managers on operational energy consumption and indoor air quality as well as a signal when systems need maintenance or repair. Being responsive to occupancy means that a smart ventilation system can adjust ventilation depending on demand such as reducing ventilation if the building is unoccupied. Smart ventilation can time-shift ventilation to periods when a) indoor-outdoor temperature differences are smaller (and away from peak outdoor temperatures and humidity), b) when indoor-outdoor temperatures are appropriate for ventilative cooling, or c) when outdoor air quality is acceptable. Being responsive to electricity grid needs means providing flexibility to electricity demand (including direct signals from utilities) and integration with electric grid control strategies. Smart ventilation systems can have sensors to detect airflow, systems pressures, or fan energy use in such a way that systems failures can be detected and repaired, as well as when system components need maintenance, such as filter replacement.[36]

Ventilation and combustion

[edit]

Combustion (in a fireplace, gas heater, candle, oil lamp, etc.) consumes oxygen while producing carbon dioxide and other unhealthy gases and smoke, requiring ventilation air. An open chimney promotes infiltration (i.e. natural ventilation) because of the negative pressure change induced by the buoyant, warmer air leaving through the chimney. The warm air is typically replaced by heavier, cold air.

Ventilation in a structure is also needed for removing water vapor produced by respiration, burning, and cooking, and for removing odors. If water vapor is permitted to accumulate, it may damage the structure, insulation, or finishes. [citation needed] When operating, an air conditioner usually removes excess moisture from the air. A dehumidifier may also be appropriate for removing airborne moisture.

Calculation for acceptable ventilation rate

[edit]

Ventilation guidelines are based on the minimum ventilation rate required to maintain acceptable levels of effluents. Carbon dioxide is used as a reference point, as it is the gas of highest emission at a relatively constant value of 0.005 L/s. The mass balance equation is:

Q = G/(Ci − Ca)

  • Q = ventilation rate (L/s)
  • G = CO2 generation rate
  • Ci = acceptable indoor CO2 concentration
  • Ca = ambient CO2 concentration[37]

Smoking and ventilation

[edit]

ASHRAE standard 62 states that air removed from an area with environmental tobacco smoke shall not be recirculated into ETS-free air. A space with ETS requires more ventilation to achieve similar perceived air quality to that of a non-smoking environment.

The amount of ventilation in an ETS area is equal to the amount of an ETS-free area plus the amount V, where:

V = DSD × VA × A/60E

  • V = recommended extra flow rate in CFM (L/s)
  • DSD = design smoking density (estimated number of cigarettes smoked per hour per unit area)
  • VA = volume of ventilation air per cigarette for the room being designed (ft3/cig)
  • E = contaminant removal effectiveness[38]

History

[edit]
This ancient Roman house uses a variety of passive cooling and passive ventilation techniques. Heavy masonry walls, small exterior windows, and a narrow walled garden oriented N-S shade the house, preventing heat gain. The house opens onto a central atrium with an impluvium (open to the sky); the evaporative cooling of the water causes a cross-draft from atrium to garden.

Primitive ventilation systems were found at the Pločnik archeological site (belonging to the Vinča culture) in Serbia and were built into early copper smelting furnaces. The furnace, built on the outside of the workshop, featured earthen pipe-like air vents with hundreds of tiny holes in them and a prototype chimney to ensure air goes into the furnace to feed the fire and smoke comes out safely.[39]

Passive ventilation and passive cooling systems were widely written about around the Mediterranean by Classical times. Both sources of heat and sources of cooling (such as fountains and subterranean heat reservoirs) were used to drive air circulation, and buildings were designed to encourage or exclude drafts, according to climate and function. Public bathhouses were often particularly sophisticated in their heating and cooling. Icehouses are some millennia old, and were part of a well-developed ice industry by classical times.

The development of forced ventilation was spurred by the common belief in the late 18th and early 19th century in the miasma theory of disease, where stagnant 'airs' were thought to spread illness. An early method of ventilation was the use of a ventilating fire near an air vent which would forcibly cause the air in the building to circulate. English engineer John Theophilus Desaguliers provided an early example of this when he installed ventilating fires in the air tubes on the roof of the House of Commons. Starting with the Covent Garden Theatre, gas burning chandeliers on the ceiling were often specially designed to perform a ventilating role.

Mechanical systems

[edit]
The Central Tower of the Palace of Westminster. This octagonal spire was for ventilation purposes, in the more complex system imposed by Reid on Barry, in which it was to draw air out of the Palace. The design was for the aesthetic disguise of its function.[40][41]

A more sophisticated system involving the use of mechanical equipment to circulate the air was developed in the mid-19th century. A basic system of bellows was put in place to ventilate Newgate Prison and outlying buildings, by the engineer Stephen Hales in the mid-1700s. The problem with these early devices was that they required constant human labor to operate. David Boswell Reid was called to testify before a Parliamentary committee on proposed architectural designs for the new House of Commons, after the old one burned down in a fire in 1834.[40] In January 1840 Reid was appointed by the committee for the House of Lords dealing with the construction of the replacement for the Houses of Parliament. The post was in the capacity of ventilation engineer, in effect; and with its creation there began a long series of quarrels between Reid and Charles Barry, the architect.[42]

Reid advocated the installation of a very advanced ventilation system in the new House. His design had air being drawn into an underground chamber, where it would undergo either heating or cooling. It would then ascend into the chamber through thousands of small holes drilled into the floor, and would be extracted through the ceiling by a special ventilation fire within a great stack.[43]

Reid's reputation was made by his work in Westminster. He was commissioned for an air quality survey in 1837 by the Leeds and Selby Railway in their tunnel.[44] The steam vessels built for the Niger expedition of 1841 were fitted with ventilation systems based on Reid's Westminster model.[45] Air was dried, filtered and passed over charcoal.[46][47] Reid's ventilation method was also applied more fully to St. George's Hall, Liverpool, where the architect, Harvey Lonsdale Elmes, requested that Reid should be involved in ventilation design.[48] Reid considered this the only building in which his system was completely carried out.[49]

Fans

[edit]

With the advent of practical steam power, ceiling fans could finally be used for ventilation. Reid installed four steam-powered fans in the ceiling of St George's Hospital in Liverpool, so that the pressure produced by the fans would force the incoming air upward and through vents in the ceiling. Reid's pioneering work provides the basis for ventilation systems to this day.[43] He was remembered as "Dr. Reid the ventilator" in the twenty-first century in discussions of energy efficiency, by Lord Wade of Chorlton.[50]

History and development of ventilation rate standards

[edit]

Ventilating a space with fresh air aims to avoid "bad air". The study of what constitutes bad air dates back to the 1600s when the scientist Mayow studied asphyxia of animals in confined bottles.[51] The poisonous component of air was later identified as carbon dioxide (CO2), by Lavoisier in the very late 1700s, starting a debate as to the nature of "bad air" which humans perceive to be stuffy or unpleasant. Early hypotheses included excess concentrations of CO2 and oxygen depletion. However, by the late 1800s, scientists thought biological contamination, not oxygen or CO2, was the primary component of unacceptable indoor air. However, it was noted as early as 1872 that CO2 concentration closely correlates to perceived air quality.

The first estimate of minimum ventilation rates was developed by Tredgold in 1836.[52] This was followed by subsequent studies on the topic by Billings [53] in 1886 and Flugge in 1905. The recommendations of Billings and Flugge were incorporated into numerous building codes from 1900–the 1920s and published as an industry standard by ASHVE (the predecessor to ASHRAE) in 1914.[51]

The study continued into the varied effects of thermal comfort, oxygen, carbon dioxide, and biological contaminants. The research was conducted with human subjects in controlled test chambers. Two studies, published between 1909 and 1911, showed that carbon dioxide was not the offending component. Subjects remained satisfied in chambers with high levels of CO2, so long as the chamber remained cool.[51] (Subsequently, it has been determined that CO2 is, in fact, harmful at concentrations over 50,000ppm[54])

ASHVE began a robust research effort in 1919. By 1935, ASHVE-funded research conducted by Lemberg, Brandt, and Morse – again using human subjects in test chambers – suggested the primary component of "bad air" was an odor, perceived by the human olfactory nerves.[55] Human response to odor was found to be logarithmic to contaminant concentrations, and related to temperature. At lower, more comfortable temperatures, lower ventilation rates were satisfactory. A 1936 human test chamber study by Yaglou, Riley, and Coggins culminated much of this effort, considering odor, room volume, occupant age, cooling equipment effects, and recirculated air implications, which guided ventilation rates.[56] The Yaglou research has been validated, and adopted into industry standards, beginning with the ASA code in 1946. From this research base, ASHRAE (having replaced ASHVE) developed space-by-space recommendations, and published them as ASHRAE Standard 62-1975: Ventilation for acceptable indoor air quality.

As more architecture incorporated mechanical ventilation, the cost of outdoor air ventilation came under some scrutiny. In 1973, in response to the 1973 oil crisis and conservation concerns, ASHRAE Standards 62-73 and 62–81) reduced required ventilation from 10 CFM (4.76 L/s) per person to 5 CFM (2.37 L/s) per person. In cold, warm, humid, or dusty climates, it is preferable to minimize ventilation with outdoor air to conserve energy, cost, or filtration. This critique (e.g. Tiller[57]) led ASHRAE to reduce outdoor ventilation rates in 1981, particularly in non-smoking areas. However subsequent research by Fanger,[58] W. Cain, and Janssen validated the Yaglou model. The reduced ventilation rates were found to be a contributing factor to sick building syndrome.[59]

The 1989 ASHRAE standard (Standard 62–89) states that appropriate ventilation guidelines are 20 CFM (9.2 L/s) per person in an office building, and 15 CFM (7.1 L/s) per person for schools, while 2004 Standard 62.1-2004 has lower recommendations again (see tables below). ANSI/ASHRAE (Standard 62–89) speculated that "comfort (odor) criteria are likely to be satisfied if the ventilation rate is set so that 1,000 ppm CO2 is not exceeded"[60] while OSHA has set a limit of 5000 ppm over 8 hours.[61]

Historical ventilation rates
Author or source Year Ventilation rate (IP) Ventilation rate (SI) Basis or rationale
Tredgold 1836 4 CFM per person 2 L/s per person Basic metabolic needs, breathing rate, and candle burning
Billings 1895 30 CFM per person 15 L/s per person Indoor air hygiene, preventing spread of disease
Flugge 1905 30 CFM per person 15 L/s per person Excessive temperature or unpleasant odor
ASHVE 1914 30 CFM per person 15 L/s per person Based on Billings, Flugge and contemporaries
Early US Codes 1925 30 CFM per person 15 L/s per person Same as above
Yaglou 1936 15 CFM per person 7.5 L/s per person Odor control, outdoor air as a fraction of total air
ASA 1946 15 CFM per person 7.5 L/s per person Based on Yahlou and contemporaries
ASHRAE 1975 15 CFM per person 7.5 L/s per person Same as above
ASHRAE 1981 10 CFM per person 5 L/s per person For non-smoking areas, reduced.
ASHRAE 1989 15 CFM per person 7.5 L/s per person Based on Fanger, W. Cain, and Janssen

ASHRAE continues to publish space-by-space ventilation rate recommendations, which are decided by a consensus committee of industry experts. The modern descendants of ASHRAE standard 62-1975 are ASHRAE Standard 62.1, for non-residential spaces, and ASHRAE 62.2 for residences.

In 2004, the calculation method was revised to include both an occupant-based contamination component and an area–based contamination component.[62] These two components are additive, to arrive at an overall ventilation rate. The change was made to recognize that densely populated areas were sometimes overventilated (leading to higher energy and cost) using a per-person methodology.

Occupant Based Ventilation Rates,[62] ANSI/ASHRAE Standard 62.1-2004

IP Units SI Units Category Examples
0 cfm/person 0 L/s/person Spaces where ventilation requirements are primarily associated with building elements, not occupants. Storage Rooms, Warehouses
5 cfm/person 2.5 L/s/person Spaces occupied by adults, engaged in low levels of activity Office space
7.5 cfm/person 3.5 L/s/person Spaces where occupants are engaged in higher levels of activity, but not strenuous, or activities generating more contaminants Retail spaces, lobbies
10 cfm/person 5 L/s/person Spaces where occupants are engaged in more strenuous activity, but not exercise, or activities generating more contaminants Classrooms, school settings
20 cfm/person 10 L/s/person Spaces where occupants are engaged in exercise, or activities generating many contaminants dance floors, exercise rooms

Area-based ventilation rates,[62] ANSI/ASHRAE Standard 62.1-2004

IP Units SI Units Category Examples
0.06 cfm/ft2 0.30 L/s/m2 Spaces where space contamination is normal, or similar to an office environment Conference rooms, lobbies
0.12 cfm/ft2 0.60 L/s/m2 Spaces where space contamination is significantly higher than an office environment Classrooms, museums
0.18 cfm/ft2 0.90 L/s/m2 Spaces where space contamination is even higher than the previous category Laboratories, art classrooms
0.30 cfm/ft2 1.5 L/s/m2 Specific spaces in sports or entertainment where contaminants are released Sports, entertainment
0.48 cfm/ft2 2.4 L/s/m2 Reserved for indoor swimming areas, where chemical concentrations are high Indoor swimming areas

The addition of occupant- and area-based ventilation rates found in the tables above often results in significantly reduced rates compared to the former standard. This is compensated in other sections of the standard which require that this minimum amount of air is delivered to the breathing zone of the individual occupant at all times. The total outdoor air intake of the ventilation system (in multiple-zone variable air volume (VAV) systems) might therefore be similar to the airflow required by the 1989 standard.
From 1999 to 2010, there was considerable development of the application protocol for ventilation rates. These advancements address occupant- and process-based ventilation rates, room ventilation effectiveness, and system ventilation effectiveness[63]

Problems

[edit]
  • In hot, humid climates, unconditioned ventilation air can daily deliver approximately 260 milliliters of water for each cubic meters per hour (m3/h) of outdoor air (or one pound of water each day for each cubic feet per minute of outdoor air per day), annual average.[citation needed] This is a great deal of moisture and can create serious indoor moisture and mold problems. For example, given a 150 m2 building with an airflow of 180 m3/h this could result in about 47 liters of water accumulated per day.
  • Ventilation efficiency is determined by design and layout, and is dependent upon the placement and proximity of diffusers and return air outlets. If they are located closely together, supply air may mix with stale air, decreasing the efficiency of the HVAC system, and creating air quality problems.
  • System imbalances occur when components of the HVAC system are improperly adjusted or installed and can create pressure differences (too much-circulating air creating a draft or too little circulating air creating stagnancy).
  • Cross-contamination occurs when pressure differences arise, forcing potentially contaminated air from one zone to an uncontaminated zone. This often involves undesired odors or VOCs.
  • Re-entry of exhaust air occurs when exhaust outlets and fresh air intakes are either too close, prevailing winds change exhaust patterns or infiltration between intake and exhaust air flows.
  • Entrainment of contaminated outdoor air through intake flows will result in indoor air contamination. There are a variety of contaminated air sources, ranging from industrial effluent to VOCs put off by nearby construction work.[64] A recent study revealed that in urban European buildings equipped with ventilation systems lacking outdoor air filtration, the exposure to outdoor-originating pollutants indoors resulted in more Disability-Adjusted Life Years (DALYs) than exposure to indoor-emitted pollutants.[65]

See also

[edit]
  • Architectural engineering
  • Biological safety
  • Cleanroom
  • Environmental tobacco smoke
  • Fume hood
  • Head-end power
  • Heating, ventilation, and air conditioning
  • Heat recovery ventilation
  • Mechanical engineering
  • Room air distribution
  • Sick building syndrome
  • Siheyuan
  • Solar chimney
  • Tulou
  • Windcatcher

References

[edit]
  1. ^ Malone, Alanna. "The Windcatcher House". Architectural Record: Building for Social Change. McGraw-Hill. Archived from the original on 22 April 2012.
  2. ^ ASHRAE (2021). "Ventilation and Infiltration". ASHRAE Handbook—Fundamentals. Peachtree Corners, GA: ASHRAE. ISBN 978-1-947192-90-4.
  3. ^ a b Whole-House Ventilation | Department of Energy
  4. ^ de Gids W.F., Jicha M., 2010. "Ventilation Information Paper 32: Hybrid Ventilation Archived 2015-11-17 at the Wayback Machine", Air Infiltration and Ventilation Centre (AIVC), 2010
  5. ^ Schiavon, Stefano (2014). "Adventitious ventilation: a new definition for an old mode?". Indoor Air. 24 (6): 557–558. Bibcode:2014InAir..24..557S. doi:10.1111/ina.12155. ISSN 1600-0668. PMID 25376521.
  6. ^ ANSI/ASHRAE Standard 62.1, Ventilation for Acceptable Indoor Air Quality, ASHRAE, Inc., Atlanta, GA, US
  7. ^ Belias, Evangelos; Licina, Dusan (2024). "European residential ventilation: Investigating the impact on health and energy demand". Energy and Buildings. 304. Bibcode:2024EneBu.30413839B. doi:10.1016/j.enbuild.2023.113839.
  8. ^ Belias, Evangelos; Licina, Dusan (2022). "Outdoor PM2. 5 air filtration: optimising indoor air quality and energy". Building & Cities. 3 (1): 186–203. doi:10.5334/bc.153.
  9. ^ Belias, Evangelos; Licina, Dusan (2024). "European residential ventilation: Investigating the impact on health and energy demand". Energy and Buildings. 304. Bibcode:2024EneBu.30413839B. doi:10.1016/j.enbuild.2023.113839.
  10. ^ Belias, Evangelos; Licina, Dusan (2023). "Influence of outdoor air pollution on European residential ventilative cooling potential". Energy and Buildings. 289. Bibcode:2023EneBu.28913044B. doi:10.1016/j.enbuild.2023.113044.
  11. ^ a b Sun, Y., Zhang, Y., Bao, L., Fan, Z. and Sundell, J., 2011. Ventilation and dampness in dorms and their associations with allergy among college students in China: a case-control study. Indoor Air, 21(4), pp.277-283.
  12. ^ Kavanaugh, Steve. Infiltration and Ventilation In Residential Structures. February 2004
  13. ^ M.H. Sherman. "ASHRAE's First Residential Ventilation Standard" (PDF). Lawrence Berkeley National Laboratory. Archived from the original (PDF) on 29 February 2012.
  14. ^ a b ASHRAE Standard 62
  15. ^ How Natural Ventilation Works by Steven J. Hoff and Jay D. Harmon. Ames, IA: Department of Agricultural and Biosystems Engineering, Iowa State University, November 1994.
  16. ^ "Natural Ventilation – Whole Building Design Guide". Archived from the original on 21 July 2012.
  17. ^ Shaqe, Erlet. Sustainable Architectural Design.
  18. ^ "Natural Ventilation for Infection Control in Health-Care Settings" (PDF). World Health Organization (WHO), 2009. Retrieved 5 July 2021.
  19. ^ Escombe, A. R.; Oeser, C. C.; Gilman, R. H.; et al. (2007). "Natural ventilation for the prevention of airborne contagion". PLOS Med. 4 (68): e68. doi:10.1371/journal.pmed.0040068. PMC 1808096. PMID 17326709.
  20. ^ Centers For Disease Control and Prevention (CDC) "Improving Ventilation In Buildings". 11 February 2020.
  21. ^ Centers For Disease Control and Prevention (CDC) "Guidelines for Environmental Infection Control in Health-Care Facilities". 22 July 2019.
  22. ^ Dr. Edward A. Nardell Professor of Global Health and Social Medicine, Harvard Medical School "If We're Going to Live With COVID-19, It's Time to Clean Our Indoor Air Properly". Time. February 2022.
  23. ^ "A Paradigm Shift to Combat Indoor Respiratory Infection - 21st century" (PDF). University of Leeds., Morawska, L, Allen, J, Bahnfleth, W et al. (36 more authors) (2021) A paradigm shift to combat indoor respiratory infection. Science, 372 (6543). pp. 689-691. ISSN 0036-8075
  24. ^ Video "Building Ventilation What Everyone Should Know". YouTube. 17 June 2022.
  25. ^ Mudarri, David (January 2010). Public Health Consequences and Cost of Climate Change Impacts on Indoor Environments (PDF) (Report). The Indoor Environments Division, Office of Radiation and Indoor Air, U.S. Environmental Protection Agency. pp. 38–39, 63.
  26. ^ "Climate Change a Systems Perspective". Cassbeth.
  27. ^ Raatschen W. (ed.), 1990: "Demand Controlled Ventilation Systems: State of the Art Review Archived 2014-05-08 at the Wayback Machine", Swedish Council for Building Research, 1990
  28. ^ Mansson L.G., Svennberg S.A., Liddament M.W., 1997: "Technical Synthesis Report. A Summary of IEA Annex 18. Demand Controlled Ventilating Systems Archived 2016-03-04 at the Wayback Machine", UK, Air Infiltration and Ventilation Centre (AIVC), 1997
  29. ^ ASHRAE (2006). "Interpretation IC 62.1-2004-06 Of ANSI/ASHRAE Standard 62.1-2004 Ventilation For Acceptable Indoor Air Quality" (PDF). American Society of Heating, Refrigerating, and Air-Conditioning Engineers. p. 2. Archived from the original (PDF) on 12 August 2013. Retrieved 10 April 2013.
  30. ^ Fahlen P., Andersson H., Ruud S., 1992: "Demand Controlled Ventilation Systems: Sensor Tests Archived 2016-03-04 at the Wayback Machine", Swedish National Testing and Research Institute, Boras, 1992
  31. ^ Raatschen W., 1992: "Demand Controlled Ventilation Systems: Sensor Market Survey Archived 2016-03-04 at the Wayback Machine", Swedish Council for Building Research, 1992
  32. ^ Mansson L.G., Svennberg S.A., 1993: "Demand Controlled Ventilation Systems: Source Book Archived 2016-03-04 at the Wayback Machine", Swedish Council for Building Research, 1993
  33. ^ Lin X, Lau J & Grenville KY. (2012). "Evaluation of the Validity of the Assumptions Underlying CO2-Based Demand-Controlled Ventilation by a Literature review" (PDF). ASHRAE Transactions NY-14-007 (RP-1547). Archived from the original (PDF) on 14 July 2014. Retrieved 10 July 2014.
  34. ^ ASHRAE (2010). "ANSI/ASHRAE Standard 90.1-2010: Energy Standard for Buildings Except for Low-Rise Residential Buildings". American Society of Heating Ventilation and Air Conditioning Engineers, Atlanta, GA.
  35. ^ a b "Ventilation. - 1926.57". Osha.gov. Archived from the original on 2 December 2012. Retrieved 10 November 2012.
  36. ^ Air Infiltration and Ventilation Centre (AIVC). "What is smart ventilation?", AIVC, 2018
  37. ^ "Home". Wapa.gov. Archived from the original on 26 July 2011. Retrieved 10 November 2012.
  38. ^ ASHRAE, Ventilation for Acceptable Indoor Air Quality. American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc, Atlanta, 2002.
  39. ^ "Stone Pages Archaeo News: Neolithic Vinca was a metallurgical culture". www.stonepages.com. Archived from the original on 30 December 2016. Retrieved 11 August 2016.
  40. ^ a b Porter, Dale H. (1998). The Life and Times of Sir Goldsworthy Gurney: Gentleman scientist and inventor, 1793–1875. Associated University Presses, Inc. pp. 177–79. ISBN 0-934223-50-5.
  41. ^ "The Towers of Parliament". www.parliament.UK. Archived from the original on 17 January 2012.
  42. ^ Alfred Barry (1867). "The life and works of Sir Charles Barry, R.A., F.R.S., &c. &c". Retrieved 29 December 2011.
  43. ^ a b Robert Bruegmann. "Central Heating and Ventilation: Origins and Effects on Architectural Design" (PDF).
  44. ^ Russell, Colin A; Hudson, John (2011). Early Railway Chemistry and Its Legacy. Royal Society of Chemistry. p. 67. ISBN 978-1-84973-326-7. Retrieved 29 December 2011.
  45. ^ Milne, Lynn. "McWilliam, James Ormiston". Oxford Dictionary of National Biography (online ed.). Oxford University Press. doi:10.1093/ref:odnb/17747. (Subscription or UK public library membership required.)
  46. ^ Philip D. Curtin (1973). The image of Africa: British ideas and action, 1780–1850. Vol. 2. University of Wisconsin Press. p. 350. ISBN 978-0-299-83026-7. Retrieved 29 December 2011.
  47. ^ "William Loney RN – Background". Peter Davis. Archived from the original on 6 January 2012. Retrieved 7 January 2012.
  48. ^ Sturrock, Neil; Lawsdon-Smith, Peter (10 June 2009). "David Boswell Reid's Ventilation of St. George's Hall, Liverpool". The Victorian Web. Archived from the original on 3 December 2011. Retrieved 7 January 2012.
  49. ^ Lee, Sidney, ed. (1896). "Reid, David Boswell" . Dictionary of National Biography. Vol. 47. London: Smith, Elder & Co.
  50. ^ Great Britain: Parliament: House of Lords: Science and Technology Committee (15 July 2005). Energy Efficiency: 2nd Report of Session 2005–06. The Stationery Office. p. 224. ISBN 978-0-10-400724-2. Retrieved 29 December 2011.
  51. ^ a b c Janssen, John (September 1999). "The History of Ventilation and Temperature Control" (PDF). ASHRAE Journal. American Society of Heating Refrigeration and Air Conditioning Engineers, Atlanta, GA. Archived (PDF) from the original on 14 July 2014. Retrieved 11 June 2014.
  52. ^ Tredgold, T. 1836. "The Principles of Warming and Ventilation – Public Buildings". London: M. Taylor
  53. ^ Billings, J.S. 1886. "The principles of ventilation and heating and their practical application 2d ed., with corrections" Archived copy. OL 22096429M.
  54. ^ "Immediately Dangerous to Life or Health Concentrations (IDLH): Carbon dioxide – NIOSH Publications and Products". CDC. May 1994. Archived from the original on 20 April 2018. Retrieved 30 April 2018.
  55. ^ Lemberg WH, Brandt AD, and Morse, K. 1935. "A laboratory study of minimum ventilation requirements: ventilation box experiments". ASHVE Transactions, V. 41
  56. ^ Yaglou CPE, Riley C, and Coggins DI. 1936. "Ventilation Requirements" ASHVE Transactions, v.32
  57. ^ Tiller, T.R. 1973. ASHRAE Transactions, v. 79
  58. ^ Berg-Munch B, Clausen P, Fanger PO. 1984. "Ventilation requirements for the control of body odor in spaces occupied by women". Proceedings of the 3rd Int. Conference on Indoor Air Quality, Stockholm, Sweden, V5
  59. ^ Joshi, SM (2008). "The sick building syndrome". Indian J Occup Environ Med. 12 (2): 61–64. doi:10.4103/0019-5278.43262. PMC 2796751. PMID 20040980. in section 3 "Inadequate ventilation"
  60. ^ "Standard 62.1-2004: Stricter or Not?" ASHRAE IAQ Applications, Spring 2006. "Archived copy" (PDF). Archived from the original (PDF) on 14 July 2014. Retrieved 12 June 2014.cite web: CS1 maint: archived copy as title (link) accessed 11 June 2014
  61. ^ Apte, Michael G. Associations between indoor CO2 concentrations and sick building syndrome symptoms in U.S. office buildings: an analysis of the 1994–1996 BASE study data." Indoor Air, Dec 2000: 246–58.
  62. ^ a b c Stanke D. 2006. "Explaining Science Behind Standard 62.1-2004". ASHRAE IAQ Applications, V7, Summer 2006. "Archived copy" (PDF). Archived from the original (PDF) on 14 July 2014. Retrieved 12 June 2014.cite web: CS1 maint: archived copy as title (link) accessed 11 June 2014
  63. ^ Stanke, DA. 2007. "Standard 62.1-2004: Stricter or Not?" ASHRAE IAQ Applications, Spring 2006. "Archived copy" (PDF). Archived from the original (PDF) on 14 July 2014. Retrieved 12 June 2014.cite web: CS1 maint: archived copy as title (link) accessed 11 June 2014
  64. ^ US EPA. Section 2: Factors Affecting Indoor Air Quality. "Archived copy" (PDF). Archived (PDF) from the original on 24 October 2008. Retrieved 30 April 2009.cite web: CS1 maint: archived copy as title (link)
  65. ^ Belias, Evangelos; Licina, Dusan (2024). "European residential ventilation: Investigating the impact on health and energy demand". Energy and Buildings. 304. Bibcode:2024EneBu.30413839B. doi:10.1016/j.enbuild.2023.113839.
[edit]

Air Infiltration & Ventilation Centre (AIVC)

[edit]
  • Publications from the Air Infiltration & Ventilation Centre (AIVC)

International Energy Agency (IEA) Energy in Buildings and Communities Programme (EBC)

[edit]
  • Publications from the International Energy Agency (IEA) Energy in Buildings and Communities Programme (EBC) ventilation-related research projects-annexes:
    • EBC Annex 9 Minimum Ventilation Rates
    • EBC Annex 18 Demand Controlled Ventilation Systems
    • EBC Annex 26 Energy Efficient Ventilation of Large Enclosures
    • EBC Annex 27 Evaluation and Demonstration of Domestic Ventilation Systems
    • EBC Annex 35 Control Strategies for Hybrid Ventilation in New and Retrofitted Office Buildings (HYBVENT)
    • EBC Annex 62 Ventilative Cooling

International Society of Indoor Air Quality and Climate

[edit]
  • Indoor Air Journal
  • Indoor Air Conference Proceedings

American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)

[edit]
  • ASHRAE Standard 62.1 – Ventilation for Acceptable Indoor Air Quality
  • ASHRAE Standard 62.2 – Ventilation for Acceptable Indoor Air Quality in Residential Buildings

 

 

External heat exchanger of an air-source heat pump for both heating and cooling
Mitsubishi heat pump interior air handler wall unit

A heat pump is a device that consumes energy (usually electricity) to transfer heat from a cold heat sink to a hot heat sink. Specifically, the heat pump transfers thermal energy using a refrigeration cycle, cooling the cool space and warming the warm space.[1] In cold weather, a heat pump can move heat from the cool outdoors to warm a house (e.g. winter); the pump may also be designed to move heat from the house to the warmer outdoors in warm weather (e.g. summer). As they transfer heat rather than generating heat, they are more energy-efficient than other ways of heating or cooling a home.[2]

A gaseous refrigerant is compressed so its pressure and temperature rise. When operating as a heater in cold weather, the warmed gas flows to a heat exchanger in the indoor space where some of its thermal energy is transferred to that indoor space, causing the gas to condense to its liquid state. The liquified refrigerant flows to a heat exchanger in the outdoor space where the pressure falls, the liquid evaporates and the temperature of the gas falls. It is now colder than the temperature of the outdoor space being used as a heat source. It can again take up energy from the heat source, be compressed and repeat the cycle.

Air source heat pumps are the most common models, while other types include ground source heat pumps, water source heat pumps and exhaust air heat pumps.[3] Large-scale heat pumps are also used in district heating systems.[4]

The efficiency of a heat pump is expressed as a coefficient of performance (COP), or seasonal coefficient of performance (SCOP). The higher the number, the more efficient a heat pump is. For example, an air-to-water heat pump that produces 6kW at a SCOP of 4.62 will give over 4kW of energy into a heating system for every kilowatt of energy that the heat pump uses itself to operate. When used for space heating, heat pumps are typically more energy-efficient than electric resistance and other heaters.

Because of their high efficiency and the increasing share of fossil-free sources in electrical grids, heat pumps are playing a role in climate change mitigation.[5][6] Consuming 1 kWh of electricity, they can transfer 1[7] to 4.5 kWh of thermal energy into a building. The carbon footprint of heat pumps depends on how electricity is generated, but they usually reduce emissions.[8] Heat pumps could satisfy over 80% of global space and water heating needs with a lower carbon footprint than gas-fired condensing boilers: however, in 2021 they only met 10%.[4]

Principle of operation

[edit]
A: indoor compartment, B: outdoor compartment, I: insulation, 1: condenser, 2: expansion valve, 3: evaporator, 4: compressor

Heat flows spontaneously from a region of higher temperature to a region of lower temperature. Heat does not flow spontaneously from lower temperature to higher, but it can be made to flow in this direction if work is performed. The work required to transfer a given amount of heat is usually much less than the amount of heat; this is the motivation for using heat pumps in applications such as the heating of water and the interior of buildings.[9]

The amount of work required to drive an amount of heat Q from a lower-temperature reservoir such as ambient air to a higher-temperature reservoir such as the interior of a building is: where

  • is the work performed on the working fluid by the heat pump's compressor.
  • is the heat transferred from the lower-temperature reservoir to the higher-temperature reservoir.
  • is the instantaneous coefficient of performance for the heat pump at the temperatures prevailing in the reservoirs at one instant.

The coefficient of performance of a heat pump is greater than one so the work required is less than the heat transferred, making a heat pump a more efficient form of heating than electrical resistance heating. As the temperature of the higher-temperature reservoir increases in response to the heat flowing into it, the coefficient of performance decreases, causing an increasing amount of work to be required for each unit of heat being transferred.[9]

The coefficient of performance, and the work required by a heat pump can be calculated easily by considering an ideal heat pump operating on the reversed Carnot cycle:

  • If the low-temperature reservoir is at a temperature of 270 K (−3 °C) and the interior of the building is at 280 K (7 °C) the relevant coefficient of performance is 27. This means only 1 joule of work is required to transfer 27 joules of heat from a reservoir at 270 K to another at 280 K. The one joule of work ultimately ends up as thermal energy in the interior of the building so for each 27 joules of heat that are removed from the low-temperature reservoir, 28 joules of heat are added to the building interior, making the heat pump even more attractive from an efficiency perspective.[note 1]
  • As the temperature of the interior of the building rises progressively to 300 K (27 °C) the coefficient of performance falls progressively to 9. This means each joule of work is responsible for transferring 9 joules of heat out of the low-temperature reservoir and into the building. Again, the 1 joule of work ultimately ends up as thermal energy in the interior of the building so 10 joules of heat are added to the building interior.[note 2]

This is the theoretical amount of heat pumped but in practice it will be less for various reasons, for example if the outside unit has been installed where there is not enough airflow. More data sharing with owners and academics—perhaps from heat meters—could improve efficiency in the long run.[11]

History

[edit]

Milestones:

1748
William Cullen demonstrates artificial refrigeration.[12]
1834
Jacob Perkins patents a design for a practical refrigerator using dimethyl ether.[13]
1852
Lord Kelvin describes the theory underlying heat pumps.[14]
1855–1857
Peter von Rittinger develops and builds the first heat pump.[15]
1877
In the period before 1875, heat pumps were for the time being pursued for vapour compression evaporation (open heat pump process) in salt works with their obvious advantages for saving wood and coal. In 1857, Peter von Rittinger was the first to try to implement the idea of vapor compression in a small pilot plant. Presumably inspired by Rittinger's experiments in Ebensee, Antoine-Paul Piccard from the University of Lausanne and the engineer J. H. Weibel from the Weibel–Briquet company in Geneva built the world's first really functioning vapor compression system with a two-stage piston compressor. In 1877 this first heat pump in Switzerland was installed in the Bex salt works.[14][16]
1928
Aurel Stodola constructs a closed-loop heat pump (water source from Lake Geneva) which provides heating for the Geneva city hall to this day.[17]
1937–1945
During the First World War, fuel prices were very high in Switzerland but it had plenty of hydropower.[14]: 18  In the period before and especially during the Second World War, when neutral Switzerland was completely surrounded by fascist-ruled countries, the coal shortage became alarming again. Thanks to their leading position in energy technology, the Swiss companies Sulzer, Escher Wyss and Brown Boveri built and put in operation around 35 heat pumps between 1937 and 1945. The main heat sources were lake water, river water, groundwater, and waste heat. Particularly noteworthy are the six historic heat pumps from the city of Zurich with heat outputs from 100 kW to 6 MW. An international milestone is the heat pump built by Escher Wyss in 1937/38 to replace the wood stoves in the City Hall of Zurich. To avoid noise and vibrations, a recently developed rotary piston compressor was used. This historic heat pump heated the town hall for 63 years until 2001. Only then was it replaced by a new, more efficient heat pump.[14]
1945
John Sumner, City Electrical Engineer for Norwich, installs an experimental water-source heat pump fed central heating system, using a nearby river to heat new Council administrative buildings. It had a seasonal efficiency ratio of 3.42, average thermal delivery of 147 kW, and peak output of 234 kW.[18]
1948
Robert C. Webber is credited as developing and building the first ground-source heat pump.[19]
1951
First large scale installation—the Royal Festival Hall in London is opened with a town gas-powered reversible water-source heat pump, fed by the Thames, for both winter heating and summer cooling needs.[18]
2019
The Kigali Amendment to phase out harmful refrigerants takes effect.

Types

[edit]

Air-source

[edit]
Heat pump on balcony of apartment

An air source heat pump (ASHP) is a heat pump that can absorb heat from air outside a building and release it inside; it uses the same vapor-compression refrigeration process and much the same equipment as an air conditioner, but in the opposite direction. ASHPs are the most common type of heat pump and, usually being smaller, tend to be used to heat individual houses or flats rather than blocks, districts or industrial processes.[20][21]

Air-to-air heat pumps provide hot or cold air directly to rooms, but do not usually provide hot water. Air-to-water heat pumps use radiators or underfloor heating to heat a whole house and are often also used to provide domestic hot water.

An ASHP can typically gain 4 kWh thermal energy from 1 kWh electric energy. They are optimized for flow temperatures between 30 and 40 °C (86 and 104 °F), suitable for buildings with heat emitters sized for low flow temperatures. With losses in efficiency, an ASHP can even provide full central heating with a flow temperature up to 80 °C (176 °F).[22]

As of 2023 about 10% of building heating worldwide is from ASHPs. They are the main way to phase out gas boilers (also known as "furnaces") from houses, to avoid their greenhouse gas emissions.[23]

Air-source heat pumps are used to move heat between two heat exchangers, one outside the building which is fitted with fins through which air is forced using a fan and the other which either directly heats the air inside the building or heats water which is then circulated around the building through radiators or underfloor heating which releases the heat to the building. These devices can also operate in a cooling mode where they extract heat via the internal heat exchanger and eject it into the ambient air using the external heat exchanger. Some can be used to heat water for washing which is stored in a domestic hot water tank.[24]

Air-source heat pumps are relatively easy and inexpensive to install, so are the most widely used type. In mild weather, coefficient of performance (COP) may be between 2 and 5, while at temperatures below around −8 °C (18 °F) an air-source heat pump may still achieve a COP of 1 to 4.[25]

While older air-source heat pumps performed relatively poorly at low temperatures and were better suited for warm climates, newer models with variable-speed compressors remain highly efficient in freezing conditions allowing for wide adoption and cost savings in places like Minnesota and Maine in the United States.[26]

Ground source

[edit]
 
A heat pump in combination with heat and cold storage

A ground source heat pump (also geothermal heat pump) is a heating/cooling system for buildings that use a type of heat pump to transfer heat to or from the ground, taking advantage of the relative constancy of temperatures of the earth through the seasons. Ground-source heat pumps (GSHPs) – or geothermal heat pumps (GHP), as they are commonly termed in North America – are among the most energy-efficient technologies for providing HVAC and water heating, using far less energy than can be achieved by burning a fuel in a boiler/furnace or by use of resistive electric heaters.

Efficiency is given as a coefficient of performance (CoP) which is typically in the range 3 – 6, meaning that the devices provide 3 – 6 units of heat for each unit of electricity used. Setup costs are higher than for other heating systems, due to the requirement to install ground loops over large areas or to drill bore holes, and for this reason, ground source is often suitable when new blocks of flats are built.[27] Otherwise air-source heat pumps are often used instead.

Heat recovery ventilation

[edit]

Exhaust air heat pumps extract heat from the exhaust air of a building and require mechanical ventilation. Two classes exist:

  • Exhaust air-air heat pumps transfer heat to intake air.
  • Exhaust air-water heat pumps transfer heat to a heating circuit that includes a tank of domestic hot water.

Solar-assisted

[edit]
 
Hybrid photovoltaic-thermal solar panels of a SAHP in an experimental installation at Department of Energy at Polytechnic of Milan

A solar-assisted heat pump (SAHP) is a machine that combines a heat pump and thermal solar panels and/or PV solar panels in a single integrated system.[28] Typically these two technologies are used separately (or only placing them in parallel) to produce hot water.[29] In this system the solar thermal panel performs the function of the low temperature heat source and the heat produced is used to feed the heat pump's evaporator.[30] The goal of this system is to get high coefficient of performance (COP) and then produce energy in a more efficient and less expensive way.

It is possible to use any type of solar thermal panel (sheet and tubes, roll-bond, heat pipe, thermal plates) or hybrid (mono/polycrystalline, thin film) in combination with the heat pump. The use of a hybrid panel is preferable because it allows covering a part of the electricity demand of the heat pump and reduce the power consumption and consequently the variable costs of the system.

Water-source

[edit]
Water-source heat exchanger being installed

A water-source heat pump works in a similar manner to a ground-source heat pump, except that it takes heat from a body of water rather than the ground. The body of water does, however, need to be large enough to be able to withstand the cooling effect of the unit without freezing or creating an adverse effect for wildlife.[31] The largest water-source heat pump was installed in the Danish town of Esbjerg in 2023.[32][33]

Others

[edit]

A thermoacoustic heat pump operates as a thermoacoustic heat engine without refrigerant but instead uses a standing wave in a sealed chamber driven by a loudspeaker to achieve a temperature difference across the chamber.[34]

Electrocaloric heat pumps are solid state.[35]

Applications

[edit]

The International Energy Agency estimated that, as of 2021, heat pumps installed in buildings have a combined capacity of more than 1000 GW.[4] They are used for heating, ventilation, and air conditioning (HVAC) and may also provide domestic hot water and tumble clothes drying.[36] The purchase costs are supported in various countries by consumer rebates.[37]

Space heating and sometimes also cooling

[edit]

In HVAC applications, a heat pump is typically a vapor-compression refrigeration device that includes a reversing valve and optimized heat exchangers so that the direction of heat flow (thermal energy movement) may be reversed. The reversing valve switches the direction of refrigerant through the cycle and therefore the heat pump may deliver either heating or cooling to a building.

Because the two heat exchangers, the condenser and evaporator, must swap functions, they are optimized to perform adequately in both modes. Therefore, the Seasonal Energy Efficiency Rating (SEER in the US) or European seasonal energy efficiency ratio of a reversible heat pump is typically slightly less than those of two separately optimized machines. For equipment to receive the US Energy Star rating, it must have a rating of at least 14 SEER. Pumps with ratings of 18 SEER or above are considered highly efficient. The highest efficiency heat pumps manufactured are up to 24 SEER.[38]

Heating seasonal performance factor (in the US) or Seasonal Performance Factor (in Europe) are ratings of heating performance. The SPF is Total heat output per annum / Total electricity consumed per annum in other words the average heating COP over the year.[39]

Window mounted heat pump

[edit]
Saddle-style window mounted heat pump 3D sketch

Window mounted heat pumps run on standard 120v AC outlets and provide heating, cooling, and humidity control. They are more efficient with lower noise levels, condensation management, and a smaller footprint than window mounted air conditioners that just do cooling.[40]

Water heating

[edit]

In water heating applications, heat pumps may be used to heat or preheat water for swimming pools, homes or industry. Usually heat is extracted from outdoor air and transferred to an indoor water tank.[41][42]

District heating

[edit]

Large (megawatt-scale) heat pumps are used for district heating.[43] However as of 2022 about 90% of district heat is from fossil fuels.[44] In Europe, heat pumps account for a mere 1% of heat supply in district heating networks but several countries have targets to decarbonise their networks between 2030 and 2040.[4] Possible sources of heat for such applications are sewage water, ambient water (e.g. sea, lake and river water), industrial waste heat, geothermal energy, flue gas, waste heat from district cooling and heat from solar seasonal thermal energy storage.[45] Large-scale heat pumps for district heating combined with thermal energy storage offer high flexibility for the integration of variable renewable energy. Therefore, they are regarded as a key technology for limiting climate change by phasing out fossil fuels.[45][46] They are also a crucial element of systems which can both heat and cool districts.[47]

Industrial heating

[edit]

There is great potential to reduce the energy consumption and related greenhouse gas emissions in industry by application of industrial heat pumps, for example for process heat.[48][49] Short payback periods of less than 2 years are possible, while achieving a high reduction of CO2 emissions (in some cases more than 50%).[50][51] Industrial heat pumps can heat up to 200 °C, and can meet the heating demands of many light industries.[52][53] In Europe alone, 15 GW of heat pumps could be installed in 3,000 facilities in the paper, food and chemicals industries.[4]

Performance

[edit]

The performance of a heat pump is determined by the ability of the pump to extract heat from a low temperature environment (the source) and deliver it to a higher temperature environment (the sink).[54] Performance varies, depending on installation details, temperature differences, site elevation, location on site, pipe runs, flow rates, and maintenance.

In general, heat pumps work most efficiently (that is, the heat output produced for a given energy input) when the difference between the heat source and the heat sink is small. When using a heat pump for space or water heating, therefore, the heat pump will be most efficient in mild conditions, and decline in efficiency on very cold days. Performance metrics supplied to consumers attempt to take this variation into account.

Common performance metrics are the SEER (in cooling mode) and seasonal coefficient of performance (SCOP) (commonly used just for heating), although SCOP can be used for both modes of operation.[54] Larger values of either metric indicate better performance.[54] When comparing the performance of heat pumps, the term performance is preferred to efficiency, with coefficient of performance (COP) being used to describe the ratio of useful heat movement per work input.[54] An electrical resistance heater has a COP of 1.0, which is considerably lower than a well-designed heat pump which will typically have a COP of 3 to 5 with an external temperature of 10 °C and an internal temperature of 20 °C. Because the ground is a constant temperature source, a ground-source heat pump is not subjected to large temperature fluctuations, and therefore is the most energy-efficient type of heat pump.[54]

The "seasonal coefficient of performance" (SCOP) is a measure of the aggregate energy efficiency measure over a period of one year which is dependent on regional climate.[54] One framework for this calculation is given by the Commission Regulation (EU) No. 813/2013.[55]

A heat pump's operating performance in cooling mode is characterized in the US by either its energy efficiency ratio (EER) or seasonal energy efficiency ratio (SEER), both of which have units of BTU/(h·W) (note that 1 BTU/(h·W) = 0.293 W/W) and larger values indicate better performance.

COP variation with output temperature
Pump type and source Typical use 35 °C
(e.g. heated screed floor)
45 °C
(e.g. heated screed floor)
55 °C
(e.g. heated timber floor)
65 °C
(e.g. radiator or DHW)
75 °C
(e.g. radiator and DHW)
85 °C
(e.g. radiator and DHW)
High-efficiency air-source heat pump (ASHP), air at −20 °C[56]   2.2 2.0 ‐ ‐ ‐ ‐
Two-stage ASHP, air at −20 °C[57] Low source temperature 2.4 2.2 1.9 ‐ ‐ ‐
High-efficiency ASHP, air at 0 °C[56] Low output temperature 3.8 2.8 2.2 2.0 ‐ ‐
Prototype transcritical CO
2
(R744) heat pump with tripartite gas cooler, source at 0 °C[58]
High output temperature 3.3 ‐ ‐ 4.2 ‐ 3.0
Ground-source heat pump (GSHP), water at 0 °C[56]   5.0 3.7 2.9 2.4 ‐ ‐
GSHP, ground at 10 °C[56] Low output temperature 7.2 5.0 3.7 2.9 2.4 ‐
Theoretical Carnot cycle limit, source −20 °C   5.6 4.9 4.4 4.0 3.7 3.4
Theoretical Carnot cycle limit, source 0 °C   8.8 7.1 6.0 5.2 4.6 4.2
Theoretical Lorentzen cycle limit (CO
2
pump), return fluid 25 °C, source 0 °C[58]
  10.1 8.8 7.9 7.1 6.5 6.1
Theoretical Carnot cycle limit, source 10 °C   12.3 9.1 7.3 6.1 5.4 4.8

Carbon footprint

[edit]

The carbon footprint of heat pumps depends on their individual efficiency and how electricity is produced. An increasing share of low-carbon energy sources such as wind and solar will lower the impact on the climate.

heating system emissions of energy source efficiency resulting emissions for thermal energy
heat pump with onshore wind power 11 gCO2/kWh[59] 400% (COP=4) 3 gCO2/kWh
heat pump with global electricity mix 436 gCO2/kWh[60] (2022) 400% (COP=4) 109 gCO2/kWh
natural-gas thermal (high efficiency) 201 gCO2/kWh[61] 90%[citation needed] 223 gCO2/kWh
heat pump
electricity by lignite (old power plant)
and low performance
1221 gCO2/kWh[61] 300% (COP=3) 407 gCO2/kWh

In most settings, heat pumps will reduce CO2 emissions compared to heating systems powered by fossil fuels.[62] In regions accounting for 70% of world energy consumption, the emissions savings of heat pumps compared with a high-efficiency gas boiler are on average above 45% and reach 80% in countries with cleaner electricity mixes.[4] These values can be improved by 10 percentage points, respectively, with alternative refrigerants. In the United States, 70% of houses could reduce emissions by installing a heat pump.[63][4] The rising share of renewable electricity generation in many countries is set to increase the emissions savings from heat pumps over time.[4]

Heating systems powered by green hydrogen are also low-carbon and may become competitors, but are much less efficient due to the energy loss associated with hydrogen conversion, transport and use. In addition, not enough green hydrogen is expected to be available before the 2030s or 2040s.[64][65]

Operation

[edit]
Figure 2: Temperature–entropy diagram of the vapor-compression cycle
An internal view of the outdoor unit of an Ecodan air source heat pump
Large heat pump setup for a commercial building
Wiring and connections to a central air unit inside

Vapor-compression uses a circulating refrigerant as the medium which absorbs heat from one space, compresses it thereby increasing its temperature before releasing it in another space. The system normally has eight main components: a compressor, a reservoir, a reversing valve which selects between heating and cooling mode, two thermal expansion valves (one used when in heating mode and the other when used in cooling mode) and two heat exchangers, one associated with the external heat source/sink and the other with the interior. In heating mode the external heat exchanger is the evaporator and the internal one being the condenser; in cooling mode the roles are reversed.

Circulating refrigerant enters the compressor in the thermodynamic state known as a saturated vapor[66] and is compressed to a higher pressure, resulting in a higher temperature as well. The hot, compressed vapor is then in the thermodynamic state known as a superheated vapor and it is at a temperature and pressure at which it can be condensed with either cooling water or cooling air flowing across the coil or tubes. In heating mode this heat is used to heat the building using the internal heat exchanger, and in cooling mode this heat is rejected via the external heat exchanger.

The condensed, liquid refrigerant, in the thermodynamic state known as a saturated liquid, is next routed through an expansion valve where it undergoes an abrupt reduction in pressure. That pressure reduction results in the adiabatic flash evaporation of a part of the liquid refrigerant. The auto-refrigeration effect of the adiabatic flash evaporation lowers the temperature of the liquid and-vapor refrigerant mixture to where it is colder than the temperature of the enclosed space to be refrigerated.

The cold mixture is then routed through the coil or tubes in the evaporator. A fan circulates the warm air in the enclosed space across the coil or tubes carrying the cold refrigerant liquid and vapor mixture. That warm air evaporates the liquid part of the cold refrigerant mixture. At the same time, the circulating air is cooled and thus lowers the temperature of the enclosed space to the desired temperature. The evaporator is where the circulating refrigerant absorbs and removes heat which is subsequently rejected in the condenser and transferred elsewhere by the water or air used in the condenser.

To complete the refrigeration cycle, the refrigerant vapor from the evaporator is again a saturated vapor and is routed back into the compressor.

Over time, the evaporator may collect ice or water from ambient humidity. The ice is melted through defrosting cycle. An internal heat exchanger is either used to heat/cool the interior air directly or to heat water that is then circulated through radiators or underfloor heating circuit to either heat or cool the buildings.

Improvement of coefficient of performance by subcooling

[edit]

Heat input can be improved if the refrigerant enters the evaporator with a lower vapor content. This can be achieved by cooling the liquid refrigerant after condensation. The gaseous refrigerant condenses on the heat exchange surface of the condenser. To achieve a heat flow from the gaseous flow center to the wall of the condenser, the temperature of the liquid refrigerant must be lower than the condensation temperature.

Additional subcooling can be achieved by heat exchange between relatively warm liquid refrigerant leaving the condenser and the cooler refrigerant vapor emerging from the evaporator. The enthalpy difference required for the subcooling leads to the superheating of the vapor drawn into the compressor. When the increase in cooling achieved by subcooling is greater that the compressor drive input required to overcome the additional pressure losses, such a heat exchange improves the coefficient of performance.[67]

One disadvantage of the subcooling of liquids is that the difference between the condensing temperature and the heat-sink temperature must be larger. This leads to a moderately high pressure difference between condensing and evaporating pressure, whereby the compressor energy increases.

Refrigerant choice

[edit]

Pure refrigerants can be divided into organic substances (hydrocarbons (HCs), chlorofluorocarbons (CFCs), hydrochlorofluorocarbons (HCFCs), hydrofluorocarbons (HFCs), hydrofluoroolefins (HFOs), and HCFOs), and inorganic substances (ammonia (NH
3
), carbon dioxide (CO
2
), and water (H
2O
)[68]).[69] Their boiling points are usually below −25 °C.[70]

In the past 200 years, the standards and requirements for new refrigerants have changed. Nowadays low global warming potential (GWP) is required, in addition to all the previous requirements for safety, practicality, material compatibility, appropriate atmospheric life,[clarification needed] and compatibility with high-efficiency products. By 2022, devices using refrigerants with a very low GWP still have a small market share but are expected to play an increasing role due to enforced regulations,[71] as most countries have now ratified the Kigali Amendment to ban HFCs.[72] Isobutane (R600A) and propane (R290) are far less harmful to the environment than conventional hydrofluorocarbons (HFC) and are already being used in air-source heat pumps.[73] Propane may be the most suitable for high temperature heat pumps.[74] Ammonia (R717) and carbon dioxide (R-744) also have a low GWP. As of 2023 smaller CO
2
heat pumps are not widely available and research and development of them continues.[75] A 2024 report said that refrigerants with GWP are vulnerable to further international restrictions.[76]

Until the 1990s, heat pumps, along with fridges and other related products used chlorofluorocarbons (CFCs) as refrigerants, which caused major damage to the ozone layer when released into the atmosphere. Use of these chemicals was banned or severely restricted by the Montreal Protocol of August 1987.[77]

Replacements, including R-134a and R-410A, are hydrofluorocarbons (HFC) with similar thermodynamic properties with insignificant ozone depletion potential (ODP) but had problematic GWP.[78] HFCs are powerful greenhouse gases which contribute to climate change.[79][80] Dimethyl ether (DME) also gained in popularity as a refrigerant in combination with R404a.[81] More recent refrigerants include difluoromethane (R32) with a lower GWP, but still over 600.

refrigerant 20-year GWP 100-year GWP
R-290 propane[82] 0.072 0.02
R-600a isobutane   3[83]
R-32[82] 491 136
R-410a[84] 4705 2285
R-134a[84] 4060 1470
R-404a[84] 7258 4808

Devices with R-290 refrigerant (propane) are expected to play a key role in the future.[74][85] The 100-year GWP of propane, at 0.02, is extremely low and is approximately 7000 times less than R-32. However, the flammability of propane requires additional safety measures: the maximum safe charges have been set significantly lower than for lower flammability refrigerants (only allowing approximately 13.5 times less refrigerant in the system than R-32).[86][87][88] This means that R-290 is not suitable for all situations or locations. Nonetheless, by 2022, an increasing number of devices with R-290 were offered for domestic use, especially in Europe.[citation needed]

At the same time,[when?] HFC refrigerants still dominate the market. Recent government mandates have seen the phase-out of R-22 refrigerant. Replacements such as R-32 and R-410A are being promoted as environmentally friendly but still have a high GWP.[89] A heat pump typically uses 3 kg of refrigerant. With R-32 this amount still has a 20-year impact equivalent to 7 tons of CO2, which corresponds to two years of natural gas heating in an average household. Refrigerants with a high ODP have already been phased out.[citation needed]

Government incentives

[edit]

Financial incentives aim to protect consumers from high fossil gas costs and to reduce greenhouse gas emissions,[90] and are currently available in more than 30 countries around the world, covering more than 70% of global heating demand in 2021.[4]

Australia

[edit]

Food processors, brewers, petfood producers and other industrial energy users are exploring whether it is feasible to use renewable energy to produce industrial-grade heat. Process heating accounts for the largest share of onsite energy use in Australian manufacturing, with lower-temperature operations like food production particularly well-suited to transition to renewables.

To help producers understand how they could benefit from making the switch, the Australian Renewable Energy Agency (ARENA) provided funding to the Australian Alliance for Energy Productivity (A2EP) to undertake pre-feasibility studies at a range of sites around Australia, with the most promising locations advancing to full feasibility studies.[91]

In an effort to incentivize energy efficiency and reduce environmental impact, the Australian states of Victoria, New South Wales, and Queensland have implemented rebate programs targeting the upgrade of existing hot water systems. These programs specifically encourage the transition from traditional gas or electric systems to heat pump based systems.[92][93][94][95][96]

Canada

[edit]

In 2022, the Canada Greener Homes Grant[97] provides up to $5000 for upgrades (including certain heat pumps), and $600 for energy efficiency evaluations.

China

[edit]

Purchase subsidies in rural areas in the 2010s reduced burning coal for heating, which had been causing ill health.[98]

In the 2024 report by the International Energy Agency (IEA) titled "The Future of Heat Pumps in China," it is highlighted that China, as the world's largest market for heat pumps in buildings, plays a critical role in the global industry. The country accounts for over one-quarter of global sales, with a 12% increase in 2023 alone, despite a global sales dip of 3% the same year.[99]

Heat pumps are now used in approximately 8% of all heating equipment sales for buildings in China as of 2022, and they are increasingly becoming the norm in central and southern regions for both heating and cooling. Despite their higher upfront costs and relatively low awareness, heat pumps are favored for their energy efficiency, consuming three to five times less energy than electric heaters or fossil fuel-based solutions. Currently, decentralized heat pumps installed in Chinese buildings represent a quarter of the global installed capacity, with a total capacity exceeding 250 GW, which covers around 4% of the heating needs in buildings.[99]

Under the Announced Pledges Scenario (APS), which aligns with China's carbon neutrality goals, the capacity is expected to reach 1,400 GW by 2050, meeting 25% of heating needs. This scenario would require an installation of about 100 GW of heat pumps annually until 2050. Furthermore, the heat pump sector in China employs over 300,000 people, with employment numbers expected to double by 2050, underscoring the importance of vocational training for industry growth. This robust development in the heat pump market is set to play a significant role in reducing direct emissions in buildings by 30% and cutting PM2.5 emissions from residential heating by nearly 80% by 2030.[99][100]

European Union

[edit]

To speed up the deployment rate of heat pumps, the European Commission launched the Heat Pump Accelerator Platform in November 2024.[101] It will encourage industry experts, policymakers, and stakeholders to collaborate, share best practices and ideas, and jointly discuss measures that promote sustainable heating solutions.[102]

United Kingdom

[edit]

As of 2022: heat pumps have no Value Added Tax (VAT) although in Northern Ireland they are taxed at the reduced rate of 5% instead of the usual level of VAT of 20% for most other products.[103] As of 2022 the installation cost of a heat pump is more than a gas boiler, but with the "Boiler Upgrade Scheme"[104] government grant and assuming electricity/gas costs remain similar their lifetime costs would be similar on average.[105] However lifetime cost relative to a gas boiler varies considerably depending on several factors, such as the quality of the heat pump installation and the tariff used.[106] In 2024 England was criticised for still allowing new homes to be built with gas boilers, unlike some other counties where this is banned.[107]

United States

[edit]

The High-efficiency Electric Home Rebate Program was created in 2022 to award grants to State energy offices and Indian Tribes in order to establish state-wide high-efficiency electric-home rebates. Effective immediately, American households are eligible for a tax credit to cover the costs of buying and installing a heat pump, up to $2,000. Starting in 2023, low- and moderate-level income households will be eligible for a heat-pump rebate of up to $8,000.[108]

In 2022, more heat pumps were sold in the United States than natural gas furnaces.[109]

In November 2023 Biden's administration allocated 169 million dollars from the Inflation Reduction Act to speed up production of heat pumps. It used the Defense Production Act to do so, because according to the administration, energy that is better for the climate is also better for national security.[110]

Notes

[edit]
  1. ^ As explained in Coefficient of performance TheoreticalMaxCOP = (desiredIndoorTempC + 273) ÷ (desiredIndoorTempC - outsideTempC) = (7+273) ÷ (7 - (-3)) = 280÷10 = 28 [10]
  2. ^ As explained in Coefficient of performance TheoreticalMaxCOP = (desiredIndoorTempC + 273) ÷ (desiredIndoorTempC - outsideTempC) = (27+273) ÷ (27 - (-3)) = 300÷30 = 10[10]

References

[edit]
  1. ^ "Heat Pump Systems". Energy.gov. Retrieved 26 March 2024.
  2. ^ "Heat Pump Systems". US Department of Energy. Archived from the original on 27 April 2023. Retrieved 27 April 2023.
  3. ^ "Exhaust air heat pumps". Energy Saving Trust. Retrieved 22 February 2024.
  4. ^ a b c d e f g h i Technology Report: The Future of Heat Pumps. International Energy Agency (Report). November 2022. Archived from the original on 6 January 2023. Retrieved 6 January 2023. License: CC BY 4.0.
  5. ^ IPCC AR6 WG3 Ch11 2022, Sec. 11.3.4.1.
  6. ^ IPCC SR15 Ch2 2018, p. 142.
  7. ^ Everitt, Neil (11 September 2023). "Study proves heat pump efficiency at low temperatures". Cooling Post. Retrieved 22 January 2024.
  8. ^ Deetjen, Thomas A.; Walsh, Liam; Vaishnav, Parth (28 July 2021). "US residential heat pumps: the private economic potential and its emissions, health, and grid impacts". Environmental Research Letters. 16 (8): 084024. Bibcode:2021ERL....16h4024D. doi:10.1088/1748-9326/ac10dc. ISSN 1748-9326. S2CID 236486619.
  9. ^ a b G. F. C. Rogers and Y. R. Mayhew (1957), Engineering Thermodynamics, Work and Heat Transfer, Section 13.1, Longmans, Green & Company Limited.
  10. ^ a b "Is there some theoretical maximum coefficient of performance (COP) for heat pumps and chillers?". Physics Stack Exchange. Retrieved 22 February 2024.
  11. ^ Williamson, Chris (13 October 2022). "Heat pumps are great. Let's make them even better". All you can heat. Retrieved 22 February 2024.
  12. ^ "The often forgotten Scottish inventor whose innovation changed the world". The National. 10 April 2022. Retrieved 21 February 2024.
  13. ^ Bathe, Greville; Bathe, Dorothy (1943). Jacob Perkins, his inventions, his times, & his contemporaries. The Historical Society of Pennsylvania. p. 149.
  14. ^ a b c d "History of Heat Pumping Technologies in Switzerland – Texts". www.aramis.admin.ch. Archived from the original on 23 November 2021. Retrieved 14 September 2023.
  15. ^ Banks, David L. (6 May 2008). An Introduction to Thermogeology: Ground Source Heating and Cooling (PDF). Wiley-Blackwell. ISBN 978-1-4051-7061-1. Archived (PDF) from the original on 20 December 2016. Retrieved 5 March 2014.
  16. ^ Wirth, E. (1955), Aus der Entwicklungsgeschichte der Wärmepumpe, Schweizerische Bauzeitung (in German), vol. 73, pp. 647–650, archived from the original on 20 November 2021, retrieved 20 November 2021
  17. ^ Randall, Ian (31 July 2022). "Heat pumps: The centuries-old system now at the heart of the Government's energy strategy". Daily Express. Retrieved 16 March 2024.
  18. ^ a b Electricity supply in the United Kingdom : a chronology – from the beginnings of the industry to 31 December 1985. The Electricity Council. 1987. ISBN 978-0851881058. OCLC 17343802.
  19. ^ Banks, David (August 2012). An Introduction to Thermogeology: Ground Source Heating and Cooling. John Wiley & Sons. p. 123.
  20. ^ "Why Britain's homes will need different types of heat pump". The Economist. ISSN 0013-0613. Retrieved 19 February 2024.
  21. ^ "What is an Air-Source Heat Pump? A Complete Guide In 2024". NEWNTIDE. 24 October 2024. Retrieved 30 September 2024.
  22. ^ Le, Khoa; Huang, M.J.; Hewitt, Neil (2018). "Domestic High Temperature Air Source Heat Pump: Performance Analysis Using TRNSYS Simulations". International High Performance Buildings Conference. West Lafayette, IN, USA: 5th International High Performance Buildings Conference at Purdue University: 1. Retrieved 20 February 2022.
  23. ^ "Heat pumps show how hard decarbonisation will be". The Economist. ISSN 0013-0613. Retrieved 14 September 2023.
  24. ^ Lawrence, Karen. "Air source heat pumps explained". Which?. Archived from the original on 4 October 2022. Retrieved 4 October 2022.
  25. ^ Canada, Natural Resources (22 April 2009). "Heating and Cooling With a Heat Pump". natural-resources.canada.ca. Retrieved 22 February 2024.
  26. ^ "Heat pumps do work in the cold – Americans just don't know it yet". Grist. 9 May 2022. Archived from the original on 9 May 2022. Retrieved 9 May 2022.
  27. ^ "Heat pumps are hot items. But for people living in condos, getting one presents some challenges".
  28. ^ Sezen, Kutbay; Gungor, Afsin (1 January 2023). "Comparison of solar assisted heat pump systems for heating residences: A review". Solar Energy. 249: 424–445. doi:10.1016/j.solener.2022.11.051. ISSN 0038-092X. Photovoltaic-thermal direct expansion solar assisted heat pump (PV/T-DX-SAHP) system enables to benefit the waste heat for evaporation of refrigerant in PV/T collector-evaporator, while providing better cooling for PV cells (Yao et al., 2020).
  29. ^ "Solar-assisted heat pumps". Archived from the original on 28 February 2020. Retrieved 21 June 2016.
  30. ^ "Pompe di calore elio-assistite" (in Italian). Archived from the original on 7 January 2012. Retrieved 21 June 2016.
  31. ^ Energy Saving Trust (13 February 2019). "Could a water source heat pump work for you?". Energy Saving Trust. Archived from the original on 4 October 2022. Retrieved 4 October 2022.
  32. ^ Baraniuk, Chris (29 May 2023). "The 'exploding' demand for giant heat pumps". BBC News. Archived from the original on 7 September 2023. Retrieved 19 September 2023.
  33. ^ Ristau, Oliver (24 July 2022). "Energy transition, the Danish way". DW. Archived from the original on 9 August 2023. Retrieved 19 September 2023.
  34. ^ Padavic-Callaghan, Karmela (6 December 2022). "Heat pump uses a loudspeaker and wet strips of paper to cool air". New Scientist. Archived from the original on 4 January 2023. Retrieved 4 January 2023.
  35. ^ Everitt, Neil (14 August 2023). "Scientists claim solid-state heat pump breakthrough". Cooling Post. Archived from the original on 24 September 2023. Retrieved 17 September 2023.
  36. ^ "Heat Pump Systems". U.S. Department of Energy. Archived from the original on 4 July 2017. Retrieved 5 February 2016.
  37. ^ "Renewable Heat Incentive – Domestic RHI – paid over 7 years". Ground Source Heat Pump Association. Archived from the original on 8 March 2018. Retrieved 12 March 2017.
  38. ^ "Heat Pump Efficiency | Heat Pump SEER Ratings". Carrier. Archived from the original on 14 January 2023. Retrieved 14 January 2023.
  39. ^ "COP and SPF for Heat Pumps Explained". Green Business Watch UK. 7 November 2019. Retrieved 22 February 2024.
  40. ^ "Why This Window Heat Pump is Genius – Undecided with Matt Ferrell". 11 June 2024.
  41. ^ "How it Works — Heat Pump Water Heaters (HPWHs)". www.energystar.gov. Retrieved 22 January 2024.
  42. ^ "Heat-pump hot water systems". Sustainability Victoria. Retrieved 22 January 2024.
  43. ^ Baraniuk, Chris (29 May 2023). "The 'exploding' demand for giant heat pumps". BBC News. Archived from the original on 7 September 2023. Retrieved 17 September 2023.
  44. ^ "District Heating – Energy System". IEA. Retrieved 22 January 2024.
  45. ^ a b David, Andrei; et al. (2017). "Heat Roadmap Europe: Large-Scale Electric Heat Pumps in District Heating Systems". Energies. 10 (4): 578. doi:10.3390/en10040578.
  46. ^ Sayegh, M. A.; et al. (2018). "Heat pump placement, connection and operational modes in European district heating". Energy and Buildings. 166: 122–144. Bibcode:2018EneBu.166..122S. doi:10.1016/j.enbuild.2018.02.006. Archived from the original on 14 December 2019. Retrieved 10 July 2019.
  47. ^ Buffa, Simone; et al. (2019), "5th generation district heating and cooling systems: A review of existing cases in Europe", Renewable and Sustainable Energy Reviews (in German), vol. 104, pp. 504–522, doi:10.1016/j.rser.2018.12.059
  48. ^ "Home". Annex 35. Retrieved 22 February 2024.
  49. ^ "Industrial Heat Pumps: it's time to go electric". World Business Council for Sustainable Development (WBCSD). Retrieved 22 February 2024.
  50. ^ IEA HPT TCP Annex 35 Publications Archived 2018-09-21 at the Wayback Machine
  51. ^ "Application of Industrial Heat Pumps. Annex 35 two-page summary". HPT – Heat Pumping Technologies. Retrieved 28 December 2023.
  52. ^ "Norwegian Researchers Develop World's Hottest Heat Pump". Ammonia21. 5 August 2021. Archived from the original on 23 May 2022. Retrieved 7 June 2022.
  53. ^ "Heat pumps are key to helping industry turn electric". World Business Council for Sustainable Development (WBCSD). Archived from the original on 24 September 2023. Retrieved 4 October 2022.
  54. ^ a b c d e f "Heating and cooling with a heat pump: Efficiency terminology". Natural Resources Canada. 8 September 2022. Archived from the original on 3 April 2023. Retrieved 3 April 2023.
  55. ^ Commission Regulation (EU) No 813/2013 of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for space heaters and combination heaters
  56. ^ a b c d The Canadian Renewable Energy Network 'Commercial Earth Energy Systems', Figure 29 Archived 2011-05-11 at the Wayback Machine. . Retrieved December 8, 2009.
  57. ^ Technical Institute of Physics and Chemistry, Chinese Academy of Sciences 'State of the Art of Air-source Heat Pump for Cold Region', Figure 5 Archived 2016-04-14 at the Wayback Machine. . Retrieved April 19, 2008.
  58. ^ a b SINTEF Energy Research 'Integrated CO2 Heat Pump Systems for Space Heating and DHW in low-energy and passive houses', J. Steen, Table 3.1, Table 3.3 Archived 2009-03-18 at the Wayback Machine. . Retrieved April 19, 2008.
  59. ^ "How Wind Can Help Us Breathe Easier". Energy.gov. Archived from the original on 28 August 2023. Retrieved 13 September 2023.
  60. ^ "Global Electricity Review 2023". Ember. 11 April 2023. Archived from the original on 11 April 2023. Retrieved 13 September 2023.
  61. ^ a b Quaschning 2022
  62. ^ "The UK is sabotaging its own plan to decarbonize heating". Engadget. 27 May 2021. Archived from the original on 6 June 2021. Retrieved 6 June 2021.
  63. ^ Deetjen, Thomas A; Walsh, Liam; Vaishnav, Parth (28 July 2021). "US residential heat pumps: the private economic potential and its emissions, health, and grid impacts". Environmental Research Letters. 16 (8): 084024. Bibcode:2021ERL....16h4024D. doi:10.1088/1748-9326/ac10dc. S2CID 236486619.
  64. ^ "Can the UK rely on hydrogen to save its gas boilers?". inews.co.uk. 21 May 2021. Archived from the original on 6 June 2021. Retrieved 6 June 2021.
  65. ^ IEA (2022), Global Hydrogen Review 2022, IEA, Paris https://www.iea.org/reports/global-hydrogen-review-2022 Archived 2023-01-10 at the Wayback Machine , License: CC BY 4.0
  66. ^ Saturated vapors and saturated liquids are vapors and liquids at their saturation temperature and saturation pressure. A superheated vapor is at a temperature higher than the saturation temperature corresponding to its pressure.
  67. ^ Ludwig von Cube, Hans (1981). Heat Pump Technology. Butterworths. pp. 22–23. ISBN 0-408-00497-5. Archived from the original on 3 April 2023. Retrieved 2 January 2023.
  68. ^ Chamoun, Marwan; Rulliere, Romuald; Haberschill, Philippe; Berail, Jean Francois (1 June 2012). "Dynamic model of an industrial heat pump using water as refrigerant". International Journal of Refrigeration. 35 (4): 1080–1091. doi:10.1016/j.ijrefrig.2011.12.007. ISSN 0140-7007.
  69. ^ Wu, Di (2021). "Vapor compression heat pumps with pure Low-GWP refrigerants". Renewable and Sustainable Energy Reviews. 138: 110571. doi:10.1016/j.rser.2020.110571. ISSN 1364-0321. S2CID 229455137. Archived from the original on 24 September 2023. Retrieved 17 November 2022.
  70. ^ "Everything you need to know about the wild world of heat pumps". MIT Technology Review. Archived from the original on 1 August 2023. Retrieved 19 September 2023.
  71. ^ Miara, Marek (22 October 2019). "Heat Pumps with Climate-Friendly Refrigerant Developed for Indoor Installation". Fraunhofer ISE. Archived from the original on 20 February 2022. Retrieved 21 February 2022.
  72. ^ Rabe, Barry G. (23 September 2022). "Pivoting from global climate laggard to leader: Kigali and American HFC policy". Brookings. Archived from the original on 4 October 2022. Retrieved 4 October 2022.
  73. ^ Itteilag, Richard L. (9 August 2012). Green Electricity and Global Warming. AuthorHouse. p. 77. ISBN 9781477217405. Archived from the original on 23 November 2021. Retrieved 1 November 2020.
  74. ^ a b "Propane-powered heat pumps are greener". The Economist. 6 September 2023. ISSN 0013-0613. Archived from the original on 17 September 2023. Retrieved 17 September 2023.
  75. ^ "Smart CO2 Heat Pump". www.dti.dk. Archived from the original on 30 January 2023. Retrieved 17 September 2023.
  76. ^ "Annex 53 Advanced Cooling/Refrigeration Technologies 2 page summary". HPT – Heat Pumping Technologies. Retrieved 19 February 2024.
  77. ^ "Handbook for the Montreal Protocol on Substances that Deplete the Ozone Layer – 7th Edition". United Nations Environment Programme – Ozone Secretariat. 2007. Archived from the original on 30 May 2016. Retrieved 18 December 2016.
  78. ^ "Refrigerants – Environmental Properties". The Engineering ToolBox. Archived from the original on 14 March 2013. Retrieved 12 September 2016.
  79. ^ R-410A#Environmental effects.
  80. ^ Ecometrica.com (27 June 2012). "Calculation of green house gas potential of R-410A". Archived from the original on 13 July 2015. Retrieved 13 July 2015.
  81. ^ "R404 and DME Refrigerant blend as a new solution to limit global warming potential" (PDF). 14 March 2012. Archived from the original (PDF) on 14 March 2012.
  82. ^ a b IPCC_AR6_WG1_Ch7 2021, 7SM-26
  83. ^ LearnMetrics (12 May 2023). "List of Low GWP Refrigerants: 69 Refrigerants Below 500 GWP". LearnMetrics. Archived from the original on 10 June 2023. Retrieved 13 September 2023.
  84. ^ a b c "Global warming potential (GWP) of HFC refrigerants". iifiir.org. Archived from the original on 24 September 2023. Retrieved 13 September 2023.
  85. ^ Everitt, Neil (15 September 2023). "Qvantum plant has 1 million heat pump capacity". Cooling Post. Archived from the original on 24 September 2023. Retrieved 17 September 2023.
  86. ^ Miara, Marek (22 October 2019). "Heat Pumps with Climate-Friendly Refrigerant Developed for Indoor Installation". Fraunhofer ISE. Archived from the original on 20 February 2022. Retrieved 21 February 2022.
  87. ^ "Refrigerant Safety – About Refrigerant Safety, Toxicity and Flammability". Checkmark. Retrieved 17 April 2024.
  88. ^ "A2L – Mildly Flammable Refrigerants". ACR Journal. 1 September 2015. Retrieved 17 April 2024.
  89. ^ US Environmental Protection Agency, OAR (14 November 2014). "Phaseout of Ozone-Depleting Substances (ODS)". US EPA. Archived from the original on 24 September 2015. Retrieved 16 February 2020.
  90. ^ "Heat Pumps". IEA. Archived from the original on 17 September 2023. Retrieved 17 September 2023.
  91. ^ "Electrifying industrial processes with heat pumps". 22 March 2022. Archived from the original on 8 August 2022. Retrieved 9 August 2022.
  92. ^ Department of Energy, Environment and Climate Action, Victoria Government (Australia) (11 October 2023). "Hot water systems for businesses". Victoria Government.
  93. ^ Department of Energy, Environment and Climate Action (Australia), Victoria Government (23 September 2023). "Hot water systems for households". Victoria Government.
  94. ^ New South Wales Climate and Energy Action, New South Wales Government (Australia) (8 December 2023). "Upgrade your hot water system". NSW Government.
  95. ^ Australian Government, Queensland (5 October 2023). "Queensland Business Energy Saving and Transformation Rebates". Queensland Government.
  96. ^ Time To Save (21 November 2023). "Hot Water Rebates in Australia: A Detailed Guide For Businesses". Timetosave.
  97. ^ "Canada Greener Homes Grant". 17 March 2021. Archived from the original on 17 January 2022. Retrieved 17 January 2022.
  98. ^ "Coal fired boiler replacement in Beijing rural area". Archived from the original on 24 March 2023. Retrieved 14 September 2023.
  99. ^ a b c "Executive summary – The Future of Heat Pumps in China – Analysis". IEA. Retrieved 12 April 2024.
  100. ^ IEA (2024), The Future of Heat Pumps in China, IEA, Paris https://www.iea.org/reports/the-future-of-heat-pumps-in-china, Licence: CC BY 4.0
  101. ^ "The Heat Pump Accelerator Platform". European Commission. 2024. Retrieved 27 November 2024.
  102. ^ "Heat pumps". European Commission. 2024. Retrieved 27 November 2024.
  103. ^ "HMCR rates for goods and services". 11 July 2022. Archived from the original on 22 July 2022. Retrieved 24 August 2022.
  104. ^ "Apply for the Boiler Upgrade Scheme". Archived from the original on 19 September 2023. Retrieved 14 September 2023.
  105. ^ "BBC Radio 4 – Sliced Bread, Air Source Heat Pumps". BBC. Archived from the original on 30 April 2022. Retrieved 30 April 2022.
  106. ^ Lawrence, Karen (3 May 2024). "Air source heat pump costs and savings". Which?. Retrieved 7 June 2024.
  107. ^ "Clean Heat without the Hot Air: British and Dutch lessons and challenges". UKERC. Retrieved 7 June 2024.
  108. ^ Shao, Elena. "H. R. 5376 – Inflation Reduction Act of 2022". Congress.gov. U.S. Congress. Archived from the original on 17 November 2022. Retrieved 17 November 2022.
  109. ^ "As Heat Pumps Go Mainstream, a Big Question: Can They Handle Real Cold?". The New York Times. 22 February 2023. Archived from the original on 11 April 2023. Retrieved 11 April 2023.
  110. ^ Frazin, Rachel (17 November 2023). "Biden administration uses wartime authority to bolster energy efficient manufacturing". The Hill. Retrieved 29 November 2023.

Sources

[edit]

IPCC reports

[edit]
  • IPCC (2021). Masson-Delmotte, V.; Zhai, P.; Pirani, A.; Connors, S. L.; et al. (eds.). Climate Change 2021: The Physical Science Basis (PDF). Contribution of Working Group I to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change. Cambridge University Press (In Press).
    • Forster, P.; Storelvmo, T.; Armour, K.; Collins, W. (2021). "Chapter 7: The Earth's energy budget, climate feedbacks, and climate sensitivity Supplementary Material" (PDF). IPCC AR6 WG1 2021.
  • IPCC (2018). Masson-Delmotte, V.; Zhai, P.; Pörtner, H.-O.; Roberts, D.; et al. (eds.). Global Warming of 1.5°C. An IPCC Special Report on the impacts of global warming of 1.5°C above pre-industrial levels and related global greenhouse gas emission pathways, in the context of strengthening the global response to the threat of climate change, sustainable development, and efforts to eradicate poverty (PDF). Intergovernmental Panel on Climate Change. https://www.ipcc.ch/sr15/.
    • Rogelj, J.; Shindell, D.; Jiang, K.; Fifta, S.; et al. (2018). "Chapter 2: Mitigation Pathways Compatible with 1.5°C in the Context of Sustainable Development" (PDF). IPCC SR15 2018. pp. 93–174.
  • IPCC (2022). Shula, P. R.; Skea, J.; Slade, R.; Al Khourdajie, A.; et al. (eds.). Climate Change 2022: Mitigation of Climate Change (PDF). Contribution of Working Group III to the Sixth Assessment Report of the Intergovernmental Panel on Climate Change. Cambridge, UK and New York, New York, USA: Cambridge University Press (In Press). Archived from the original (PDF) on 4 April 2022. Retrieved 10 May 2022.
    • IPCC (2022). "Industry" (PDF). IPCC AR6 WG3 2022.

Other

[edit]
  • Quaschning, Volker. "Specific Carbon Dioxide Emissions of Various Fuels". Retrieved 22 February 2022.
[edit]
  • Media related to Heat pumps at Wikimedia Commons

 

Driving Directions in Arapahoe County


Driving Directions From Mullen High School to Royal Supply South
Driving Directions From Wells Fargo ATM to Royal Supply South
Driving Directions From Denver to Royal Supply South
Driving Directions From VRCC Veterinary Specialty and Emergency Hospital to Royal Supply South
Driving Directions From Walgreens to Royal Supply South
Driving Directions From U.S. Bank ATM to Royal Supply South
Driving Directions From Aurora Reservoir to Royal Supply South
Driving Directions From Molly Brown House Museum to Royal Supply South
Driving Directions From Big Blue Bear to Royal Supply South
Driving Directions From Morrison Nature Center to Royal Supply South
Driving Directions From Aurora Reservoir to Royal Supply South
Driving Directions From Cherry Creek Valley Ecological Park to Royal Supply South

Reviews for Royal Supply South


View GBP